Return to study ST003309 main page

MB Sample ID: SA358843

Local Sample ID:May_2
Subject ID:SU003430
Subject Type:Plant
Subject Species:Pinus koraiensis
Taxonomy ID:88728

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU003430
Subject Type:Plant
Subject Species:Pinus koraiensis
Taxonomy ID:88728

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
May_2SA358843FL041893MayMonth
May_2SA358843FL041893Pinus koraiensis leafSample source
May_2SA358843FL041893MayMonth
May_2SA358843FL041893Pinus koraiensis leafSample source

Collection:

Collection ID:CO003423
Collection Summary:Fresh pine needles were collected from forests of Pinus koraiensis located in Benxi (41°4′17″ N, 124°29′58″ E, 578 m, 965.9 hPa) , Liaoning province, China. From May to September, 2020, fresh needles were collected on a monthly basis, and brought back to laboratory to prepare needle leachates. Every 150 g of fresh needles collected from Pinus koraiensis on a monthly basis during May to September were soaked in 1000 ml of sterilized water for 48 hours at room temperature, and subsequently filtered twice using qualitative filter paper through suction filtration. The aqueous leachates with a concentration of 150 g/L were stored at 4 °C for further analysis.
Sample Type:Leaf

Treatment:

Treatment ID:TR003439
Treatment Summary:No treatment

Sample Preparation:

Sampleprep ID:SP003437
Sampleprep Summary:A volume of 100 ml of leachates was extracted by 300 ml ethyl acetate (Analytical grade, Tianjin Fengchuan Chemical Reagent Co., Ltd, 426 Tianjin, China) then evaporated by rotary evaporator at 45°C with 4°C-condensed water recycled in low-temperature circulator. The remaining sediment was 429 rinsed with 2.5 ml of hexane (HPLC, EMD Millipore, Billerica, MA, USA). The liquid hexane was filtered using a 0.22 um Millipore filter (Catridge filter, Jin Teng, China) for gas chromatography-mass spectrometry (GC-MS) analysis.

Combined analysis:

Analysis ID AN005421
Analysis type MS
Chromatography type GC
Chromatography system Shimadzu GCMS-QP2010 ultra
Column Shimadzu SH-Rxi-5Sil MS (30m x 0.25mm x 0.25um)
MS Type EI
MS instrument type GC-MS
MS instrument name Shimadzu QP2010 Ultra
Ion Mode POSITIVE
Units Peak area

Chromatography:

Chromatography ID:CH004110
Chromatography Summary:The temperature program of GC-MS started from an initial temperature of 40 ℃, followed by an increase of 3 ℃/min to 80 ℃ and then an increase of 5 ℃/min from 80 ℃ to 260 ℃, which was maintained for 30 min.
Instrument Name:Shimadzu GCMS-QP2010 ultra
Column Name:Shimadzu SH-Rxi-5Sil MS (30m x 0.25mm x 0.25um)
Column Temperature:40 - 260
Flow Gradient:Not applicable
Flow Rate:Not applicable
Injection Temperature:250 ℃
Solvent A:Not applicable
Solvent B:Not applicable
Analytical Time:79.33 min
Chromatography Type:GC

MS:

MS ID:MS005147
Analysis ID:AN005421
Instrument Name:Shimadzu QP2010 Ultra
Instrument Type:GC-MS
MS Type:EI
MS Comments:The mass spectrum was recorded for the mass range 35–500 m/z and scanned at a rate of 0.3s. All the compounds identified by GCMS solutions software (Shimadzu, Kyoto, Japan) based on the comparison of its mass spectra (MS) with the NIST14 (National Institute of Standards and Technology) library.
Ion Mode:POSITIVE
  logo