Summary of Study ST000413
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000322. The data can be accessed directly via it's Project DOI: 10.21228/M8V312 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
Study ID | ST000413 |
Study Title | Metabolic profiling during ex vivo machine perfusion of the human liver (part III) |
Study Summary | As donor organ shortages persist, functional machine perfusion is under investigation to improve preservation of the donor liver. The transplantation of donation after circulatory death (DCD) livers is limited by poor outcomes, but its application may be expanded by ex vivo repair and assessment of the organ before transplantation. Here we employed subnormothermic (21 °C) machine perfusion of discarded human livers combined with metabolomics to gain insight into metabolic recovery during machine perfusion. Improvements in energetic cofactors and redox shifts were observed, as well as reversal of ischemia-induced alterations in selected pathways, including lactate metabolism and increased TCA cycle intermediates. We next evaluated whether DCD livers with steatotic and severe ischemic injury could be discriminated from ‘transplantable’ DCD livers. Metabolomic profiling was able to cluster livers with similar metabolic patterns based on the degree of injury. Moreover, perfusion parameters combined with differences in metabolic factors suggest variable mechanisms that result in poor energy recovery in injured livers. We conclude that machine perfusion combined with metabolomics has significant potential as a clinical instrument for the assessment of preserved livers. |
Institute | University of California, Davis |
Department | Genome and Biomedical Sciences Facility |
Laboratory | WCMC Metabolomics Core |
Last Name | Fiehn |
First Name | Oliver |
Address | 1315 Genome and Biomedical Sciences Facility, 451 Health Sciences Drive, Davis, CA 95616 |
ofiehn@ucdavis.edu | |
Phone | (530) 754-8258 |
Submit Date | 2016-07-01 |
Study Comments | The first 4 samples were a test run to see how efficient the analysis was and were run on a lipidomics platform. The next 12 samples were the used in the paper and were the same as the original 4 samples, but they were split into 3 biological replicates and run on the GC platform. |
Publications | doi:10.1038/srep22415 |
Raw Data Available | Yes |
Raw Data File Type(s) | d |
Analysis Type Detail | LC-MS |
Release Date | 2016-09-23 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN000653 | AN000654 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Agilent 6530 | Agilent 6550 |
Column | Waters Acquity CSH C18 (100 x 2.1mm,1.7um) | Waters Acquity CSH C18 (100 x 2.1mm,1.7um) |
MS Type | ESI | ESI |
MS instrument type | QTOF | QTOF |
MS instrument name | Agilent 6530 QTOF | Agilent 6550 QTOF |
Ion Mode | POSITIVE | NEGATIVE |
Units | counts | counts |