Return to study ST000817 main page

MB Sample ID: SA045298

Local Sample ID:Tgon_HKKO_13Cglucose_t120_A
Subject ID:SU000843
Subject Type:Cells (protozoan parasite)
Subject Species:Toxoplasma gondii
Taxonomy ID:5811
Genotype Strain:RH (Type I strain)
Cell Biosource Or Supplier:ATCC
Subject Comments:Asexual stage (Tachyzoite)
Cell Passage Number:In continuous culture
Cell Counts:10^8 cells per sample
Species Group:Microorganism

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001295
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Accela
Column Synergy Hydro-RP (Phenomenex) and Accucore C18 (Thermo)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode NEGATIVE
Units NA

Chromatography:

Chromatography ID:CH000907
Chromatography Summary:The acetonitrile:water extracts from parasites were dried under nitrogen flow and resuspended in 200 µls of water:methanol (97:3) containing 10 mM tributylamine and 15 mM acetic acid. This solvent was also used as buffer A and methanol as buffer B for liquid chromatography using a Synergy Hydro-RP column (Phenomenex) with a bed volume of 100 mm x 2 mm and particle size of 2.5 µ. For some samples, an alternate method, using a Thermo Accucore C18 column with a bed volume of 150 mm x 2.1 mm and 2.6 µ particle size. A solvent system composed of water buffered with 0.1 % formic acid (buffer A) and acetonitrile (buffer B), was used on a 20 minute gradient run with a flow rate of 200 µl/min as follows- hold at 10% acetonitrile for 30 seconds and gradually ramp up to 15%, 20%, 50%, 60% and 90% acetonitrile by 3, 6, 10, 12, 13 minutes, hold at 90% acetonitrile till 15 minutes, ramp down to 10% acetonitrile by 15.5 minutes and hold till 20 minutes. LC-MS analysis was done using a Exactive Orbitrap mass spectrometer, coupled to an Accela U-HPLC (Thermo Fisher Scientific) and HTC PAL autosampler (CTC Analytics AG). The mass spectrometer was run in negative mode, scanning a mass-charge ratio (m/z) range of 85-1000. All other parameters used for LC-MS instrumentation in this study were similar to published protocols.
Instrument Name:Thermo Accela
Column Name:Synergy Hydro-RP (Phenomenex) and Accucore C18 (Thermo)
Column Pressure:250 to 400 bar
Column Temperature:22 deg. Cel.
Flow Gradient:A solvent system composed of water buffered with 0.1 % formic acid (buffer A) and acetonitrile (buffer B), was used on a 20 minute gradient run with a flow rate of 200 µl/min as follows- hold at 10% acetonitrile for 30 seconds and gradually ramp up to 15%, 20%, 50%, 60% and 90% acetonitrile by 3, 6, 10, 12, 13 minutes, hold at 90% acetonitrile till 15 minutes, ramp down to 10% acetonitrile by 15.5 minutes and hold till 20 minutes.
Flow Rate:200 µl/min
Injection Temperature:22 deg. Cel.
Internal Standard:PIPES @ 100ng/ml final concentration
Sample Injection:10 µl
Solvent A:97% water/3% methanol; 0.1% formic acid; 15 mM acetic acid; 10 mM tributylamine
Solvent B:Methanol for Synergy Hydro-RP column. Acetonitril for accucore C18 column.
Analytical Time:20 minutes
Preconditioning:5-10 minutes
Time Program:20 minutes
Transferline Temperature:22 deg. Cel.
Washing Buffer:Methanol
Sample Loop Size:10 µl
Sample Syringe Size:100 µl
Chromatography Type:Reversed phase
  logo