Return to study ST001217 main page

MB Sample ID: SA086132

Local Sample ID:Plasma_56
Subject ID:SU001284
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Gender:Male and female

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002029 AN002030
Analysis type MS MS
Chromatography type Reversed phase HILIC
Chromatography system Agilent 6545 Agilent 6520
Column Agilent Zorbax RRHD SB-C18 (100 x 2.1mm,1.8um) Phenomenex Kinetex HILIC 100A (50 x 2.1 mm,2.6um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6545 QTOF Agilent 6520 QTOF
Ion Mode POSITIVE POSITIVE
Units Abundance (Log2) Abundance (Log2)

Chromatography:

Chromatography ID:CH001470
Chromatography Summary:Reversed phase samples from the lipid fraction were randomized in the worklist and run randomly in triplicate using an Agilent 1290 series pump with an Agilent Zorbax Rapid Resolution HD (RRHD) SB-C18, 1.8 micron (2.1 × 100 mm) analytical column and an Agilent Zorbax SB-C18, 1.8 micron (2.1 × 5 mm) guard column. The autosampler tray temperature was set at 4 °C, column temperature was set at 60 °C, and the sample injection volume was 8 µL for BAL and 4 µL for plasma. The flow rate was 0.7 mL/min with the following mobile phases: mobile phase A was water with 0.1% formic acid, and mobile phase B was 60:36:4 isopropyl alcohol:acetonitrile:water with 0.1% formic acid. Gradient elution was as follows: 0–0.5 minutes 30–70% B, 0.5–7.42 minutes 70–100% B, 7.42–10.4 minutes 100% B, 10.4–10.5 minutes 100–30% B, 10.5–15.1 minutes 30% B.
Instrument Name:Agilent 6545
Column Name:Agilent Zorbax RRHD SB-C18 (100 x 2.1mm,1.8um)
Column Temperature:60
Flow Gradient:0-0.5 minutes 30-70% B, 0.5-7.42 minutes 70-100% B, 7.42-10.4 minutes 100% B, 10.4-10.5 minutes 100-30% B, 10.5-15.1 minutes 30% B
Flow Rate:0.7 mL/min
Solvent A:100% water; 0.1% formic acid,
Solvent B:60% isopropanol/36% acetonitrile/4% water; 0.1% formic acid
Chromatography Type:Reversed phase
  
Chromatography ID:CH001471
Chromatography Summary:The samples from the aqueous small molecule fraction were analyzed randomly in triplicate using an Agilent 1290 series pump using a Phenomenex Kinetex HILIC, 2.6 µm, 100 Å (2.1 × 50 mm) analytical column and an Agilent Zorbax Eclipse Plus-C8 5 µm (2.1 × 12.5 mm) narrow bore guard column. The autosampler tray temperature was set at 4 °C, column temperature was set at 20 °C, and the sample injection volume was 1 µL for both BAL and plasma. The flow rate of 0.6 mL/min with the following mobile phases: mobile phase A was 50% ACN with pH 5.8 ammonium acetate, and mobile phase B was 90% ACN with pH 5.8 ammonium acetate. Gradient elution was as follows: 0.2 minutes 100% B, 0.2–2.1 minutes 100–90% B, 2.1–8.6 minutes 90–50% B, 8.6–8.7 minutes 50–0% B, 8.7–14.7 minutes 0% B, 14.7–14.8 minutes 0–100% B, 14.8–24.8 minutes 100% B.
Instrument Name:Agilent 6520
Column Name:Phenomenex Kinetex HILIC 100A (50 x 2.1 mm,2.6um)
Column Temperature:20
Flow Gradient:0.2 minutes 100% B, 0.2-2.1 minutes 100-90% B, 2.1-8.6 minutes 90-50% B, 8.6-8.7 minutes 50-0% B, 8.7-14.7 minutes 0% B, 14.7-14.8 minutes 0-100% B, 14.8-24.8 minutes 100% B.
Flow Rate:0.6 mL/min
Solvent A:50% acetonitrile/50% water; ammonium acetate, pH 5.8
Solvent B:90% acetonitrile/5% water, pH 5.8
Chromatography Type:HILIC
  logo