Return to study ST001644 main page
MB Sample ID: SA151407
Local Sample ID: | 31_B4_D1_RT+ |
Subject ID: | SU001721 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002689 | AN002690 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) | Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | NEGATIVE | POSITIVE |
Units | Relative Abundance | Relative Abundance |
Chromatography:
Chromatography ID: | CH001983 |
Chromatography Summary: | UHPLC-MS metabolomics analyses were performed as described,(1, 3) using a Vanquish UHPLC system coupled online to a high-resolution Q Exactive mass spectrometer (Thermo Fisher, Bremen, Germany). Samples were resolved over a Kinetex C18 column (2.1x150 mm, 1.7 µm; Phenomenex, Torrance, CA, USA) at 45°C. A volume of 10 μl of sample extracts was injected into the UHPLC-MS. Each sample was injected and run with two different chromatographic and MS conditions using a 5 minute gradient at 450 µL/minute from 5-95% B (A: 5% acetonitrile, 95%water/1 mM ammonium acetate; B:95%acetonitrile/5% water, 1 mM ammonium acetate) and the MS was operated in negative ion mode. |
Instrument Name: | Thermo Vanquish |
Column Name: | Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) |
Column Temperature: | 45 |
Flow Gradient: | 5 minute gradient from 5-95% B |
Flow Rate: | 450 µL/min |
Solvent A: | 5% acetonitrile/95% water; 1 mM ammonium acetate |
Solvent B: | 95% acetonitrile/5% water; 1 mM ammonium acetate |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH001984 |
Chromatography Summary: | UHPLC-MS metabolomics analyses were performed as described,(1, 3) using a Vanquish UHPLC system coupled online to a high-resolution Q Exactive mass spectrometer (Thermo Fisher, Bremen, Germany). Samples were resolved over a Kinetex C18 column (2.1x150 mm, 1.7 µm; Phenomenex, Torrance, CA, USA) at 45°C. A volume of 10 μl of sample extracts was injected into the UHPLC-MS. Each sample was injected and run with two different chromatographic and MS conditions, using a 5 minute gradient at 450 µL/minute from 5-95% B (A: water/0.1% formic acid; B:acetonitrile/0.1% formic acid) and the MS was operated in positive mode. |
Instrument Name: | Thermo Vanquish |
Column Name: | Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) |
Column Temperature: | 45 |
Flow Gradient: | 5 minute gradient from 5-95% B |
Flow Rate: | 450 µL/min |
Solvent A: | 5% acetonitrile/95% water; 1 mM ammonium acetate |
Solvent B: | 95% acetonitrile/5% water; 1 mM ammonium acetate |
Chromatography Type: | Reversed phase |