Return to study ST002238 main page

MB Sample ID: SA213414

Local Sample ID:81_control_NB_Plasma_Quant_HILIC_Pos_071
Subject ID:SU002324
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003651 AN003652 AN003653 AN003654
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase HILIC HILIC
Chromatography system Thermo Vanquish Thermo Vanquish Thermo Vanquish Thermo Vanquish
Column Waters Acquity BEH C18 (150 x 2mm,1.7um) Waters Acquity BEH C18 (100 x 2mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units Peak area Peak area Peak area Peak area

Chromatography:

Chromatography ID:CH002705
Chromatography Summary:Reverse phase column was eluted with 99% of mobile phase A (0.1% formic acid in water) for 0.1 min followed by a linear gradient to 100% of mobile phase B (0.1% formic acid in acetonitrile) over 15 min, then kept constant for 5 min, brought back to the initial conditions in 0.5 min, and maintained for 5 min.
Instrument Name:Thermo Vanquish
Column Name:Waters Acquity BEH C18 (150 x 2mm,1.7um)
Flow Gradient:99% of A for 0.1 min followed by a linear gradient to 100% of B over 15 min, then kept constant for 5 min, brought back to the initial conditions in 0.5 min, and maintained for 5 min.
Flow Rate:250 µl/min
Injection Temperature:40
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Randomization Order:yes
Chromatography Type:Reversed phase
  
Chromatography ID:CH002706
Chromatography Summary:Reverse phase column was eluted with 99% of mobile phase A (0.1% formic acid in water) for 0.1 min followed by a linear gradient to 100% of mobile phase B (0.1% formic acid in acetonitrile) over 15 min, then kept constant for 5 min, brought back to the initial conditions in 0.5 min, and maintained for 5 min.
Instrument Name:Thermo Vanquish
Column Name:Waters Acquity BEH C18 (100 x 2mm,1.7um)
Flow Gradient:99% of A for 0.1 min followed by a linear gradient to 100% of B over 15 min, then kept constant for 5 min, brought back to the initial conditions in 0.5 min, and maintained for 5 min.
Flow Rate:250 µl/min
Injection Temperature:40
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Randomization Order:yes
Chromatography Type:Reversed phase
  
Chromatography ID:CH002707
Chromatography Summary:HILIC column was eluted at a flow rate of 200 µl/min with 90% of mobile phase B (acetonitrile) for 0.1 min followed by a linear gradient to 70% of mobile phase A ( H2O 5 mM ammonium formate, pH 3) over 15 min, then kept constant for 5 min, brought back to the initial conditions in 0.5 min, and maintained for 9 min.
Instrument Name:Thermo Vanquish
Column Name:Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
Flow Gradient:90% of mobile phase B for 0.1 min followed by a linear gradient to 70% of mobile phase A over 15 min, then kept constant for 5 min, brought back to the initial conditions in 0.5 min, and maintained for 9 min.
Flow Rate:200 µl/min
Injection Temperature:25
Solvent A:100% water; 5 mM ammonium formate, pH 3
Solvent B:100% acetonitrile
Randomization Order:yes
Chromatography Type:HILIC
  
Chromatography ID:CH002708
Chromatography Summary:HILIC column was eluted at a flow rate of 200 µl/min with 90% of mobile phase B (acetonitrile) for 0.1 min followed by a linear gradient to 70% of mobile phase A ( H2O 5 mM ammonium formate, pH 3) over 15 min, then kept constant for 5 min, brought back to the initial conditions in 0.5 min, and maintained for 9 min.
Instrument Name:Thermo Vanquish
Column Name:Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
Flow Gradient:90% of mobile phase B for 0.1 min followed by a linear gradient to 70% of mobile phase A over 15 min, then kept constant for 5 min, brought back to the initial conditions in 0.5 min, and maintained for 9 min.
Flow Rate:200 µl/min
Injection Temperature:25
Solvent A:100% water; 5 mM ammonium formate, pH 3
Solvent B:100% acetonitrile
Randomization Order:yes
Chromatography Type:HILIC
  logo