Return to study ST003190 main page

MB Sample ID: SA347866

Local Sample ID:WT-IP8-FigS2b
Subject ID:SU003309
Subject Type:Plant
Subject Species:Arabidopsis thaliana
Taxonomy ID:3702

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005238
Analysis type MS
Chromatography type HILIC
Chromatography system Agilent 1290 Infinity
Column Agilent InfinityLab Poroshell 120 EC-C18 (100 x 3mm,2.7um)
MS Type Other
MS instrument type HPLC-MS/MS
MS instrument name Agilent 5973
Ion Mode POSITIVE
Units mg/g

Chromatography:

Chromatography ID:CH003965
Chromatography Summary:InsPs were detected using Hydrophilic Interaction High Performance Liquid Chromatography-Tandem Mass Spectrometry on an Agilent 1290 infinity HPLC system coupled to an Agilent 6460 triple Quad LC-MS/MS using InfinityLab Poroshell 120 HILIC-Z (2.1 × 100) column (Agilent Technologies, USA). Nitrogen was used as the sheath gas and drying gas. The nebulizer pressure was set to 45 psi and the flow rate of drying gas was 5 L / min. The flow rate and temperature of the sheath gas were 11 L / min and 350℃, respectively. Chromatographic separation was carried out on a HPLC column (100 × 2.1 mm, 2.7 µm). The column temperature was 35℃. The mobile phases consisted of (A) ammonium acetate in distilled water (pH 10.0) and (B) Acetonitrile. The gradient program was as follows: 0-10 min, 90 % → 55 % of B; 10-12 min, 55 % → 90 % of B; 12-20 min, 90 % of B. The flow rate was set at 0.3 ml / min, and the injection volume was 10 μl. Mass spectrometric detection was completed by use of an electrospray ionization (ESI) source in negative ion multiple-reaction monitoring (MRM) mode. InsPs were identified based on comparison to known InsPs species. The mass spectrometry parameters corresponding to different InsPs show as below: InsP3 (MRM: 419 -> 321, 419 -> 337, Acquisition time is 6-7 min); InsP4 (MRM: 499 -> 401, 499 -> 417, Acquisition time is 6-7 min); InsP5 (MRM: 579 -> 480.9, 579 -> 382.8, Acquisition time is 6-7 min); InsP6 (MRM: 659 -> 560.8, 659 -> 577, Acquisition time is 6-7 min); InsP7 (MRM: 739 -> 575, 739 -> 657, Acquisition time is 5-6 min); InsP8 (MRM: 819 -> 737, 819 -> 655, Acquisition time is 4-5 min). According to the regression equation calculated from the standard sample, substitute the response value of the sample into the equation to convert the corresponding concentration. For InsP3/InsP4/InsP5/InsP6/InsP7/InsP8 detection in seeds and seedlings, 10 g of 12-day-old seedlings or 2.4 g of dry seeds were used for InsPs enrichment with 300 mg of TiO2 beads for each sample. The enriched substances were analyzed by HPLC-MS/MS. The purchased InsP3 (1,4,5-InsP3, MedChemExpress), InsP4 (1,3,4,5-InsP4, MedChemExpress), InsP5 and InsP6, InsP7 (5-InsP7) and InsP8 (1,5-InsP8) from Lei lab25 were used as standard samples for generating the calibration curves.
Instrument Name:Agilent 1290 Infinity
Column Name:Agilent InfinityLab Poroshell 120 EC-C18 (100 x 3mm,2.7um)
Column Temperature:35℃
Flow Gradient:0-10 min, 90 % → 55 % of B; 10-12 min, 55 % → 90 % of B; 12-20 min, 90 % of B
Flow Rate:0.3 mL/min
Solvent A:100% Distilled Water; 10% ammonium acetate (pH 10.0)
Solvent B:100% Acetonitrile
Chromatography Type:HILIC