This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000800. The data can be accessed directly via it's Project DOI: 10.21228/M88M3Q This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
Study ID | ST001188 |
Study Title | P. falciparum infected erythrocytes |
Study Summary | Metabolite profiling across the 1st and 2nd intraerythrocytic developmental lifecycles of the malaria parasite P. falciparum following induction of delayed death with indolmycin treatment |
Institute | University of Melbourne |
Last Name | Cobbold |
First Name | Simon |
Address | Bio21 Institute, 30 Flemington Road |
simon.cobbold@unimelb.edu.au | |
Phone | 383442351 |
Submit Date | 2018-10-18 |
Raw Data Available | Yes |
Raw Data File Type(s) | d |
Analysis Type Detail | LC-MS |
Release Date | 2019-07-17 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN001980 |
---|---|
Analysis type | MS |
Chromatography type | HILIC |
Chromatography system | Agilent 6550 |
Column | SeQuant ZIC-HILIC (150 x 4.6mm,3.5um) |
MS Type | ESI |
MS instrument type | QTOF |
MS instrument name | Agilent 6550 QTOF |
Ion Mode | NEGATIVE |
Units | ion count |
Chromatography:
Chromatography ID: | CH001429 |
Methods Filename: | pHILIC 45 minute |
Instrument Name: | Agilent 6550 |
Column Name: | SeQuant ZIC-HILIC (150 x 4.6mm,3.5um) |
Column Pressure: | 50-150 bar |
Column Temperature: | 35 |
Flow Gradient: | 80% |
Flow Rate: | 0.3 mL/minute |
Injection Temperature: | 4 |
Solvent A: | 100% water; 20 mM ammonium formate |
Solvent B: | 100% acetonitrile |
Chromatography Type: | HILIC |