Summary of Study ST001243
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000830. The data can be accessed directly via it's Project DOI: 10.21228/M8D68Q This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001243 |
Study Title | Global Metabolic Analysis Trisomy 21 - Cohort 1 |
Study Summary | Global metabolic analysis of plasma from individuals with and without trisomy 21. |
Institute | University of Colorado Denver |
Last Name | Culp-Hill |
First Name | Rachel |
Address | 12801 E 17th Ave L18-9403D, Aurora, Colorado, 80045, USA |
rachel.hill@cuanschutz.edu | |
Phone | 303-724-5798 |
Submit Date | 2019-08-13 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2019-08-21 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002065 | AN002066 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) | Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | relative abundance | relative abundance |
Chromatography:
Chromatography ID: | CH001503 |
Chromatography Summary: | UHPLC-MS metabolomics analyses were performed using a Vanquish UHPLC system coupled online to a Q Exactive mass spectrometer (Thermo Fisher, Bremen, Germany). Samples were resolved over a Kinetex C18 column (2.1x150 mm, 1.7μm; Phenomenex, Torrance, CA, USA) at 45°C using a 4 minute gradient at 450μL/minute from 5-95% B (A: water/0.1% formic acid; B: acetonitrile/0.1% formic acid) for positive mode. To monitor possible technical variability, aliquots of each of the individual samples were combined to make technical replicates, which were run after every 15 samples. Additionally, in each experiment, several lysis solution aliquots were run as blanks for artifact identification. |
Methods Filename: | 4MMpos_method.pdf |
Instrument Name: | Thermo Vanquish |
Column Name: | Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) |
Column Temperature: | 45 |
Flow Gradient: | 5-95% B |
Flow Rate: | 450uL/min |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100% acetonitrile; 0.1% formic acid |
Chromatography Type: | Reversed phase |
Chromatography ID: | CH001504 |
Chromatography Summary: | UHPLC-MS metabolomics analyses were performed using a Vanquish UHPLC system coupled online to a Q Exactive mass spectrometer (Thermo Fisher, Bremen, Germany). Samples were resolved over a Kinetex C18 column (2.1x150 mm, 1.7μm; Phenomenex, Torrance, CA, USA) at 45°C using a 4 minute gradient at 450μL/minute from 0-100% B (A: 95% water/5% acetonitrile, 5mM NH4OAc; B: 95% acetonitrile/5% water, 5mM NH4OAc) for negative mode. To monitor possible technical variability, aliquots of each of the individual samples were combined to make technical replicates, which were run after every 15 samples. Additionally, in each experiment, several lysis solution aliquots were run as blanks for artifact identification. |
Methods Filename: | 4MMneg_method.pdf |
Instrument Name: | Thermo Vanquish |
Column Name: | Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) |
Column Temperature: | 45 |
Flow Gradient: | 0-100% B |
Flow Rate: | 450uL/min |
Solvent A: | 95% water/5% acetonitrile; 1 mM ammonium acetate |
Solvent B: | 95% acetonitrile/5% water; 1 mM ammonium acetate |
Chromatography Type: | Reversed phase |