Summary of Study ST003170

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001970. The data can be accessed directly via it's Project DOI: 10.21228/M8314P This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003170
Study TitleMetabolomics of Murine WT or MCJ KO CD19-BBz CD8 CAR-T cells rest in medium
Study SummaryMCJ/DnaJC15 is an endogenous negative regulator of Complex I and mitochondrial respiration. The goal of these experiments are to characterize the metabolic profile of murine WT or MCJ KO CD8 CD19-BBz CAR-T cells in cytokine-deprived condition. The CAR-T cells were expanded with IL-2 (60IU/ml) for 3 expansions (6 days) and rested in the medium for 48 hours.
Institute
University of Colorado School of Medicine
LaboratoryLaboratory of Angelo D'Alessandro in collaboration with Mercedes Rincon
Last NameCendali
First NameFrancesca
Address13199 East Montview Boulevard, Aurora, CO, 80045, USA
Emailfrancesca.cendali@cuanschutz.edu
Phone3037246131
Submit Date2024-04-11
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2024-05-02
Release Version1
Francesca Cendali Francesca Cendali
https://dx.doi.org/10.21228/M8314P
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005202 AN005203
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Phenomenex Kinetex C18 (150 x 2.1mm,1.7um) Phenomenex Kinetex C18 (150 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode NEGATIVE POSITIVE
Units Peak Areas Peak Areas

Chromatography:

Chromatography ID:CH003936
Chromatography Summary:Negative ion Mode
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (150 x 2.1mm,1.7um)
Column Temperature:45
Flow Gradient:0-0.5 min 0% B, 0.5-1.1 min 0-100% B, 1.1-2.75 min hold at 100% B, 2.75-3 min 100-0% B, 3-5 min hold at 0% B
Flow Rate:0.450 ml/min
Solvent A:95% water/5% acetonitrile; 1 mM ammonium acetate
Solvent B:95% acetonitrile/5% water; 1 mM ammonium acetate
Chromatography Type:Reversed phase
  
Chromatography ID:CH003937
Chromatography Summary:Positive Ion Mode
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (150 x 2.1mm,1.7um)
Column Temperature:45
Flow Gradient:0-0.5 min 5% B, 0.5-1.1 min 5-95% B, 1.1-2.75 min hold at 95% B, 2.75-3 min 95-5% B, 3-5 min hold at 5% B.
Flow Rate:0.450 ml/min
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Chromatography Type:Reversed phase
  logo