This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR002015. The data can be accessed directly via it's Project DOI: 10.21228/M85238 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003259
Study TitleExploration of EMT-dependent changes of phosphatidylethanolamine profiles in KPC allografts
Study SummaryCryo-conserved tumors from subcutaneous allografts as described (Krebs et al. 2017, DOI: 10.1038/ncb3513) were retrieved. Three tumors derived from mesenchymal KPC cell lines (lines KPC550 and KPC701) and epithelial KPC cell lines (lines KPC438 and KPC661) were analyzed for their phosphatidylethanolamine profile by UPLC-MS/MS.
Institute
University of Innsbruck
DepartmentMichael Popp Institute
Last NameKoeberle
First NameAndreas
AddressMitterweg 24, Innsbruck, Tyrol, 6020, Austria
EmailAndreas.Koeberle@uibk.ac.at
Phone+43 512 507 57903
Submit Date2024-05-27
Raw Data AvailableYes
Raw Data File Type(s)wiff
Analysis Type DetailLC-MS
Release Date2024-07-05
Release Version1
Andreas Koeberle Andreas Koeberle
https://dx.doi.org/10.21228/M85238
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005343
Analysis type MS
Chromatography type Reversed phase
Chromatography system Waters Acquity H-Class
Column Waters ACQUITY UPLC BEH C8 (100 x 2.1mm,1.7um)
MS Type ESI
MS instrument type QTRAP
MS instrument name ABI Sciex 6500+
Ion Mode NEGATIVE
Units relative intensities

Chromatography:

Chromatography ID:CH004045
Chromatography Summary:Chromatographic separation of phospholipids was carried out on an Acquity BEH C8 column (1.7 μm, 2.1×100 mm, Waters, Milford, MA) using an Acquity UHPLC.
Instrument Name:Waters Acquity H-Class
Column Name:Waters ACQUITY UPLC BEH C8 (100 x 2.1mm,1.7um)
Column Temperature:45
Flow Gradient:The gradient was ramped from 75 to 85% B over 5 min and further increased to 100% B within 2 min, followed by isocratic elution for another 2 min.
Flow Rate:0.75 mL/min
Solvent A:90% Water, 10% Acetonitrile; 2 mM ammonium acetate
Solvent B:5% Water, 95% Acetonitrile; 2 mM ammonium acetate
Chromatography Type:Reversed phase