Summary of Study ST000288
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000230. The data can be accessed directly via it's Project DOI: 10.21228/M8XG6C This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST000288 |
Study Title | Metabolomic profiling of AML Cell Lines |
Study Type | In vitro study |
Study Summary | In vitro study with AML cell lines that are treated with different concentrations of cytarabine (nucleoside analog). 8 AML cell lines were incubated for 24hr with 0uM, 1uM and 10uM ara-C. After 24hr the cells were washed and pellets were stored in -80°C for genomic and metabolomic analysis. |
Institute | University of Florida |
Department | SECIM |
Last Name | Bhise |
First Name | Neha |
Address | - |
nbhise@cop.ufl.edu | |
Phone | 352-294-5745 |
Submit Date | 2015-02-15 |
Num Groups | 3 |
Total Subjects | 24 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2016-12-22 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN000458 | AN000459 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Scientific-Dionex Ultimate 3000 | Thermo Scientific-Dionex Ultimate 3000 |
Column | ACE Excel 2 C18-PFP (100 x 2.1mm, 2um) | ACE Excel 2 C18-PFP (100 x 2.1mm, 2um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | Peak area | peak area |
Chromatography:
Chromatography ID: | CH000327 |
Methods Filename: | Metabolomics_LCMSProtocol.pdf |
Instrument Name: | Thermo Scientific-Dionex Ultimate 3000 |
Column Name: | ACE Excel 2 C18-PFP (100 x 2.1mm, 2um) |
Flow Rate: | 0.350mL/min-0.600mL/min |
Internal Standard: | Appendix A - Internal Standard Prep GLCMS.pdf |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100% acetonitrile |
Chromatography Type: | Reversed phase |