Summary of Study ST000973

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000646. The data can be accessed directly via it's Project DOI: 10.21228/M85M3S This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000973
Study TitleMetabolome profiles in urogenital schistosomiasis and associated pathologies (part II)
Study SummaryMetabolic fingerprint aid discovery of new biomarkers. Blood and urine were collected from volunteers in Eggua community, Nigeria, after ethical approval. LC-ESI-MS were used to analyse samples. Bioinformatics and statistical tools were used to detect important metabolites
Institute
University of Ibadan, Nigeria
DepartmentZoology (Cell biology and Genetics unit)
LaboratoryCentre for Materials Characterization, National Chemical Laboratory, Pune, India
Last NameAdewale
First NameAdebayo
AddressCell Biology and Genetics unit, Department of zoology, University of ibadan, Nigeria/ National Centre for Cell Science, Pune, India
Emailwalsaks@gmail.com
Phone07030710368
Submit Date2017-12-07
Publicationsdoi:10.1371/journal.pntd.0006452
Raw Data AvailableYes
Analysis Type DetailLC-MS
Release Date2018-12-11
Release Version1
Adebayo Adewale Adebayo Adewale
https://dx.doi.org/10.21228/M85M3S
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001594
Analysis type MS
Chromatography type Reversed phase
Chromatography system Q-Exactive hybrid quadrupole orbitrap mass spectrometer
Column Hypersil Gold
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE
Units abundance of specific m/z (amu)

Chromatography:

Chromatography ID:CH001119
Chromatography Summary:Both urine and plasma samples were prepared using chilled methanol:water mixture (4:1). Separation was achieved with 150mm x 2.1mm, 1.9μ Hypersil Gold column with a 5μl injection volume. Gradient elution was performed using 0.1% formic acid in water (A) and acetonitrile (B) as mobile phase after optimization. The column was washed between each sample for stability and to eliminate carry-over. The flow rate was 0.35 ml/min. MS acquisition was performed on the Q-Exactive hybrid quadrupole orbitrap mass spectrometer (ThermoFisher, MA, USA) operated in positive and negative electrospray ionization (ESI) modes. The scan range was 70 to 1000 m/z.
Instrument Name:Q-Exactive hybrid quadrupole orbitrap mass spectrometer
Column Name:Hypersil Gold
Flow Rate:0.35ml/min
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile
Chromatography Type:Reversed phase