Summary of Study ST001776

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001130. The data can be accessed directly via it's Project DOI: 10.21228/M8N706 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001776
Study TitleMetabolic Response of HEK 293 Cells Exposed to Methylmercury
Study SummaryHEK 293 cells were treated with 7.5 μM methylmercury (HgMe) for 48 h. Metabolites were extracted and subjected to LC-HRMS based metabolomics. LC-HRMS data were processed by SIEVE2.2 software. Metabolites associated with HgMe toxicity were screened and identified.
Institute
University of Macau
Last NameZhang
First Namepw
AddressTaipa, Macau SAR, China
Emailyb47620@um.edu.mo
Phone8613924251358
Submit Date2021-04-27
Raw Data AvailableYes
Raw Data File Type(s)mzXML
Analysis Type DetailLC-MS
Release Date2022-01-02
Release Version1
pw Zhang pw Zhang
https://dx.doi.org/10.21228/M8N706
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002883
Analysis type MS
Chromatography type HILIC
Chromatography system Thermo Dionex Ultimate 3000 RS
Column Thermo Accucore HILIC (100 x 2.1mm,2.6um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode POSITIVE
Units arbitray unit

Chromatography:

Chromatography ID:CH002138
Chromatography Summary:The UHPLC system was equipped with a binary pump, an autosampler and a column thermostat. The autosampler was set at 8 °C. The column oven temperature was 30 °C. Mobile phase A was 98% acetonitrile, 2% water and 0.1% formic acid while mobile phase B was 98% water, 2% acetonitrile, 30 mM ammonium formate and 0.1% formic acid. The mobile phase was freshly prepared before use. The optimized stepwise linear gradient (10% B in the first 2 min, 10% - 30% B in the next 5 min, followed by 30% - 60% in 3 min, and finally 60% - 90% in 5 min.
Instrument Name:Thermo Dionex Ultimate 3000 RS
Column Name:Thermo Accucore HILIC (100 x 2.1mm,2.6um)
Column Temperature:25
Solvent A:98% acetonitrile/2% water; 0.1% formic acid
Solvent B:98% water/2% acetonitrile; 0.1% formic acid; 30 mM ammonium formate
Sample Loop Size:10
Chromatography Type:HILIC
  logo