Summary of Study ST001925
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001215. The data can be accessed directly via it's Project DOI: 10.21228/M8NQ5X This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001925 |
Study Title | MS Untargeted Metabolomics from Human Serum |
Study Summary | Multiple Myeloma patients were treated with the proteasome inhibitor carfilzomib in different protocols according to their clinical stage. Paired serum samples were obtained before i.v injection and after 1-8h post treatment and snap frozen. Samples were stored at -80°C until analysis. |
Institute | University of Zurich |
Last Name | Mendez |
First Name | Max |
Address | Rorschacherstrasse 95. 9007, St.Gallen |
maxmendez@runbox.com | |
Phone | +41 71 494 10 67 |
Submit Date | 2021-09-21 |
Num Groups | 2 |
Total Subjects | 6 |
Num Males | 5 |
Num Females | 1 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Waters) |
Analysis Type Detail | LC-MS |
Release Date | 2022-01-02 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003128 | AN003129 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Waters Acquity | Waters Acquity |
Column | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) |
MS Type | ESI | ESI |
MS instrument type | QTOF | QTOF |
MS instrument name | Waters Xevo-TQ | Waters Xevo-TQ |
Ion Mode | NEGATIVE | POSITIVE |
Units | m/z | m/z |
Chromatography:
Chromatography ID: | CH002311 |
Chromatography Summary: | All samples were acquired by the LC-MS system followed machine orders. Firstly, all chromatographic separations were performed using an ultra performance liquid chromatography (UPLC) system (Waters, UK). An ACQUITY UPLC HSS T3 column (100 mm*2.1 mm, 1.8 μm, Waters, UK) was used for the reversed phase separation. The column oven was maintained at 50 °C. The flow rate was 0.4 ml/min and the mobile phase consisted of solvent A (water + 0.1% formic acid) and solvent B (methanol + 0.1% formic acid). Gradient elution conditions were set as follows: 0~2 min, 100% phase A; 2~11 min, 0% to 100% B; 11~13 min, 100% B; 13~15 min, 0% to 100% A. The injection volume for each sample was 5 µL. |
Instrument Name: | Waters Acquity |
Column Name: | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) |
Flow Gradient: | 0.4 ml/min |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100% methanol; 0.1% formic acid |
Chromatography Type: | Reversed phase |