Summary of Study ST002851
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001785. The data can be accessed directly via it's Project DOI: 10.21228/M8043D This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002851 |
Study Title | Metabolic caracterization of liver metastasis organotropism |
Study Summary | Transcriptomic and metabolomic analyses in animals revealed distinct metabolic adaptations, particularly related to the TCA cycle and OxPhos, specific to liver metastases compared to concurrent lung metastases. This finding was substantiated by analyzing RNA-seq data from a considerable number of patient metastases across various cancer types. Further analysis of exome/RNA-seq data from melanoma patients indicated more frequent PIK3CA mutations, lower transcript levels of PIP4K2C, and enrichment of TCA cycle and OxPhos pathways in liver metastases. |
Institute | Columbia University |
Department | Department of Medicine |
Laboratory | Division of Hematology/Oncology |
Last Name | Izar |
First Name | Benjamin |
Address | Columbia University Irving Medical Center, New York, NY, USA |
bi2175@cumc.columbia.edu | |
Phone | 0123456789 |
Submit Date | 2023-08-31 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2023-10-02 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN004670 | AN004671 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | HILIC | HILIC |
Chromatography system | Agilent 1290 Infinity II Bio LC system | Agilent 1290 Infinity II Bio LC system |
Column | Agilent AdvanceBio MS Spent Media (150 x 2.1mm, 2.7um) | Agilent AdvanceBio MS Spent Media (150 x 2.1mm, 2.7um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Plus Orbitrap | Thermo Q Exactive Plus Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | Peak Area | Peak Area |
Chromatography:
Chromatography ID: | CH003515 |
Chromatography Summary: | For liquid chromatography, an Agilent 1290 Infinity II Bio LC system (Agilent Technologies Inc., Waldbronn, Germany) consisting of a 1290 Bio High-Speed Pump, a 1290 Bio Multisampler and a 1290 MCT with an AdvanceBio MS Spent Media (150 x 2.1 mm, 2.7 µm; Agilent Technologies Inc., Waldbronn, Germany) were used. The elution was carried out by utilizing a gradient at a flow rate of 250 μL/min with water (10 mM ammonium acetate pH 9) as solvent A and acetonitrile/water (90/10; v/v; 10 mM ammonium acetate pH 9) as solvent B. The linear gradient was: 0 min, 90% B; 2 min, 90% B; 12 min, 40% B; 13 min, 20% B; 16 min, 20% B; followed by 9 min at initial condition for re-equilibration. Column temperature was 35 °C, injection volume 5 µL. |
Instrument Name: | Agilent 1290 Infinity II Bio LC system |
Column Name: | Agilent AdvanceBio MS Spent Media (150 x 2.1mm, 2.7um) |
Column Temperature: | 35 °C |
Flow Gradient: | none |
Flow Rate: | 250 μL/min |
Solvent A: | water (10 mM ammonium acetate pH 9) |
Solvent B: | acetonitrile/water (90/10; v/v; 10 mM ammonium acetate pH 9) |
Chromatography Type: | HILIC |