Summary of Study ST000605
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000442. The data can be accessed directly via it's Project DOI: 10.21228/M8XC7Q This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST000605 |
Study Title | Whole blood reveals more metabolic detail of the human metabolome than serum as measured by 1H-NMR spectroscopy: Implications for sepsis metabolomics |
Study Type | Single timepoint; healthy controls |
Study Summary | Healthy volunteers |
Institute | University of Michigan |
Department | Clinical Pharmacy |
Laboratory | The NMR Metabolomics Laboratory (Stringer) |
Last Name | Stringer |
First Name | Kathleen |
Address | University of Michigan, 2900 Huron Parkway, Ann Arbor, MI 48105 |
NMRmetabolomics@umich.edu | |
Phone | NA |
Submit Date | 2016-12-08 |
Total Subjects | 19 whole blood; 20 serum |
Raw Data Available | Yes |
Raw Data File Type(s) | fid |
Analysis Type Detail | NMR |
Release Date | 2017-01-06 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Collection:
Collection ID: | CO000622 |
Collection Summary: | Healthy - Direct venipuncture collection of WB and Serum from healthy controls | Sepsis - Indwelling arterial or venous catheter |
Collection Protocol Comments: | Healthy - Fasting (12h) blood samples (serum and whole blood) were collected between 8:30-9:30am by single direct venipuncture. | Sepsis - Serum generated via indwelling catheters as part of clinical trial (NCT 00372502) |
Sample Type: | Healthy - Blood: Whole Blood and Serum | Sepsis - Blood serum |
Collection Method: | Healthy - Direct venipuncture | Sepsis - indwelling catheters |
Collection Location: | Healthy - Michigan Clinical Research Unit | Sepsis - University of Mississippi |
Collection Frequency: | Healthy - 1 | Sepsis - 1 |
Collection Time: | Healthy - Fasting, between 0830-0930 | Sepsis - N/A |
Storage Conditions: | Healthy - Serum: Initial RT then -80°C following processing (within 2h) Whole blood: Initial 0°C then -80°C following processing (within 10mins) | Sepsis - Initial RT then -80°C following processing (within 2h) |
Storage Vials: | Healthy - SST: Becton-Dickinson vacutainer Serum Separator tubes. WB: Becton-Dickinson vacutainer Sodium Heparin tubes | Sepsis - SST: Becton-Dickinson vacutainer Serum Separator tubes |
Collection Tube Temp: | Healthy - RT | Sepsis - RT |
Additives: | Healthy - Serum: none. Whole blood: Sodium Heparin | Sepsis - none |
Blood Serum Or Plasma: | Healthy - Whole blood and Serum | Sepsis - Serum |