Return to study ST001172 main page
MB Sample ID: SA081218
Local Sample ID: | 58 |
Subject ID: | SU001237 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Gender: | Female |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN001937 | AN001938 | AN001939 | AN001940 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | HILIC | HILIC |
Chromatography system | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 |
Column | Waters Acquity BEH C18 (50 x 2.1mm,1.7um) | Waters Acquity BEH C18 (50 x 2.1mm,1.7um) | Waters Acquity BEH HILIC (150 x 2.1mm,1.7um) | Waters Acquity BEH HILIC (150 x 2.1mm,1.7um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive HF hybrid Orbitrap |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | chromatographic peak area | chromatographic peak area | chromatographic peak area | chromatographic peak area |
MS:
MS ID: | MS001793 |
Analysis ID: | AN001937 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Samples were analyzed in positive and negative ion modes for both RP and HILIC chromatography. Spectral features were extracted from the raw data using Compound Discoverer v2.1 software. |
Ion Mode: | POSITIVE |
Capillary Temperature: | 275 °C |
Spray Voltage: | 3.0 kV |
MS ID: | MS001794 |
Analysis ID: | AN001938 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Samples were analyzed in positive and negative ion modes for both RP and HILIC chromatography. Spectral features were extracted from the raw data using Compound Discoverer v2.1 software. |
Ion Mode: | NEGATIVE |
Capillary Temperature: | 275 °C |
Spray Voltage: | -2.8 kV |
MS ID: | MS001795 |
Analysis ID: | AN001939 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Samples were analyzed in positive and negative ion modes for both RP and HILIC chromatography. Spectral features were extracted from the raw data using Compound Discoverer v2.1 software. |
Ion Mode: | POSITIVE |
Capillary Temperature: | 275 °C |
Spray Voltage: | 3.0 kV |
MS ID: | MS001796 |
Analysis ID: | AN001940 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Samples were analyzed in positive and negative ion modes for both RP and HILIC chromatography. Spectral features were extracted from the raw data using Compound Discoverer v2.1 software. |
Ion Mode: | NEGATIVE |
Capillary Temperature: | 275 °C |
Spray Voltage: | -2.8 kV |