MB Sample ID: SA094741
Local Sample ID: | CQ_E2_3 |
Subject ID: | SU001389 |
Subject Type: | Cultured cells |
Subject Species: | Plasmodium falciparum |
Taxonomy ID: | 5833 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002189 | AN002190 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | HILIC | HILIC |
Chromatography system | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 |
Column | SeQuant ZIC-pHILIC (150 x 4.6mm,5um) | SeQuant ZIC-pHILIC (150 x 4.6mm,5um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | Signal Intensity | Signal Intensity |
MS:
MS ID: | MS002036 |
Analysis ID: | AN002189 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Liquid chromatography-mass spectrometry (LC-MS) data was acquired on a Q-Exactive Orbitrap mass spectrometer (Thermo Scientific) coupled with high-performance liquid chromatography system (HPLC, Dionex Ultimate® 3000 RS, Thermo Scientific) as per previously described 49. Briefly, chromatographic separation was performed on a ZIC-pHILIC column equipped with a guard (5 µm, 4.6 × 150 mm, SeQuant®, Merck). The mobile phase (A) was 20 mM ammonium carbonate (Sigma Aldrich), (B) acetonitrile (Burdick and Jackson) and needle wash solution was 50% isopropanol. The column flow rate was maintained at 0.3 ml/min with temperature at 25 ºC and the gradient program was as follows: 80% B decreasing to 50% B over 15 min, then to 5% B at 18 min until 21 min, increasing to 80% B at 24 min until 32 min. Total run time was 32 min with an injection volume of 10 µL. Mass spectrometer was operated in full scan mode with positive and negative polarity switching at 35k resolution at 200 m/z, with detection range of 85 to 1275 m/z, AGC target was 1e6 ions with a maximum injection time of 50 ms. Electro-spray ionization source (HESI) was set to 4.0 kV voltage for positive and negative mode, sheath gas was set to 50, aux gas to 20 and sweep gas to 2 arbitrary units, capillary temperature 300 °C, probe heater temperature 120 °C. The samples were analyzed as a single batch to avoid batch-to-batch variation and randomized to account for LCMS system drift over time. Repeated analysis of pooled quality control samples was performed throughout the batch to confirm signal reproducibility. |
Ion Mode: | POSITIVE |
MS ID: | MS002037 |
Analysis ID: | AN002190 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Liquid chromatography-mass spectrometry (LC-MS) data was acquired on a Q-Exactive Orbitrap mass spectrometer (Thermo Scientific) coupled with high-performance liquid chromatography system (HPLC, Dionex Ultimate® 3000 RS, Thermo Scientific) as per previously described 49. Briefly, chromatographic separation was performed on a ZIC-pHILIC column equipped with a guard (5 µm, 4.6 × 150 mm, SeQuant®, Merck). The mobile phase (A) was 20 mM ammonium carbonate (Sigma Aldrich), (B) acetonitrile (Burdick and Jackson) and needle wash solution was 50% isopropanol. The column flow rate was maintained at 0.3 ml/min with temperature at 25 ºC and the gradient program was as follows: 80% B decreasing to 50% B over 15 min, then to 5% B at 18 min until 21 min, increasing to 80% B at 24 min until 32 min. Total run time was 32 min with an injection volume of 10 µL. Mass spectrometer was operated in full scan mode with positive and negative polarity switching at 35k resolution at 200 m/z, with detection range of 85 to 1275 m/z, AGC target was 1e6 ions with a maximum injection time of 50 ms. Electro-spray ionization source (HESI) was set to 4.0 kV voltage for positive and negative mode, sheath gas was set to 50, aux gas to 20 and sweep gas to 2 arbitrary units, capillary temperature 300 °C, probe heater temperature 120 °C. The samples were analyzed as a single batch to avoid batch-to-batch variation and randomized to account for LCMS system drift over time. Repeated analysis of pooled quality control samples was performed throughout the batch to confirm signal reproducibility. |
Ion Mode: | NEGATIVE |