MB Sample ID: SA099417

Local Sample ID:MBG_5
Subject ID:SU001442
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Genotype Strain:C57BL/6J
Age Or Age Range:~11 weeks (Intervention)
Gender:Female
Animal Animal Supplier:Jackson Laboratories

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002279 AN002280 AN002281 AN002282
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase HILIC HILIC
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Waters BEH C8 (50 x 2.1mm,1.7um) Waters BEH C8 (50 x 2.1mm,1.7um) Waters HILIC (100 x 2.1mm,1.8um) Waters HILIC (100 x 2.1mm,1.8um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo LTQ-Orbitrap Velos Pro Thermo LTQ-Orbitrap Velos Pro Thermo LTQ-Orbitrap Velos Pro Thermo LTQ-Orbitrap Velos Pro
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units Abundance Abundance Abundance abundance

MS:

MS ID:MS002123
Analysis ID:AN002279
Instrument Name:Thermo LTQ-Orbitrap Velos Pro
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:For relative quantitation, the MS instrument was run in the survey scan mode with FTMS detection at a mass resolution of 60,000 FWHM at m/z 400. The mass scan range was m/z 80 to 1800, with a reference lock-mass for real-time calibration. Two UPLC-FTMS datasets were acquired for each sample, one with positive-ion detection and the other with negative-ion detection. LC-MS/MS data was also acquired from each sample set with collision induced dissociation (CID) at different levels of normalized collision energy (from publication methods).
Ion Mode:POSITIVE
  
MS ID:MS002124
Analysis ID:AN002280
Instrument Name:Thermo LTQ-Orbitrap Velos Pro
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:For relative quantitation, the MS instrument was run in the survey scan mode with FTMS detection at a mass resolution of 60,000 FWHM at m/z 400. The mass scan range was m/z 80 to 1800, with a reference lock-mass for real-time calibration. Two UPLC-FTMS datasets were acquired for each sample, one with positive-ion detection and the other with negative-ion detection. LC-MS/MS data was also acquired from each sample set with collision induced dissociation (CID) at different levels of normalized collision energy (from publication methods).
Ion Mode:NEGATIVE
  
MS ID:MS002125
Analysis ID:AN002281
Instrument Name:Thermo LTQ-Orbitrap Velos Pro
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The MS instrument was run in the survey scan mode with FTMS detection at a mass resolution of 60,000 FWHM at m/z 400. Two HILIC-FTMS datasets were acquired for each sample, one with positive-ion detection and the other with negative-ion detection. The mass scan range was m/z 80 to 800 (from publication methods).
Ion Mode:POSITIVE
  
MS ID:MS002126
Analysis ID:AN002282
Instrument Name:Thermo LTQ-Orbitrap Velos Pro
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The MS instrument was run in the survey scan mode with FTMS detection at a mass resolution of 60,000 FWHM at m/z 400. Two HILIC-FTMS datasets were acquired for each sample, one with positive-ion detection and the other with negative-ion detection. The mass scan range was m/z 80 to 800 (from publication methods).
Ion Mode:NEGATIVE