Return to study ST001384 main page
MB Sample ID: SA101077
Local Sample ID: | b391 |
Subject ID: | SU001458 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002308 | AN002309 | AN002310 | AN002311 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | Reversed phase | Reversed phase |
Chromatography system | Shimadzu Prominence 20 UFLCXR | Thermo Dionex Ultimate 3000 | Shimadzu Prominence 20 UFLCXR | Shimadzu Prominence 20 UFLCXR |
Column | Waters BEH C18 (100mm x 2.1mm; 1.7um) | Waters XSelect HSS T3 (100 x 2.1mm,2.5um) | Waters Acquity CSH C18 (100 x 2.1mm,1.7um) | Waters Acquity CSH C18 (100 x 2.1mm,1.7um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | QTOF | Orbitrap | QTOF | QTOF |
MS instrument name | ABI Sciex 5600 TripleTOF | Thermo Exactive Plus Orbitrap | ABI Sciex 5600 TripleTOF | ABI Sciex 5600 TripleTOF |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | Area | Area | Area |
MS:
MS ID: | MS002151 |
Analysis ID: | AN002308 |
Instrument Name: | ABI Sciex 5600 TripleTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | The capillary voltage was set at 4.5 kV in negative ion mode, with a declustering potential of 80V. The mass spectrometer was operated in IDA (Information Dependent Acquisition) mode with a 100 ms survey scan from 100 to 1200 m/z, and up to 20 MS/MS product ion scans (100 ms) per duty cycle using a collision energy of 50V with a 20V spread. Data processing was performed using MS-DIAL and annotated using the built-in public library. Blank subtraction and analysis was performed in excel. |
Ion Mode: | POSITIVE |
MS ID: | MS002152 |
Analysis ID: | AN002309 |
Instrument Name: | Thermo Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Aquired in MS1 mode only. Data processing and annotation performed using MAVEN and an in-house targeted list. Blank subtraction and analysis was performed in excel. |
Ion Mode: | NEGATIVE |
MS ID: | MS002153 |
Analysis ID: | AN002310 |
Instrument Name: | ABI Sciex 5600 TripleTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | IDA MS2 method. Ammonium formate and formic acid were added to the positive ESI solvents. Data processing performed using MS-DIAL and annotated using the in silico library. Blank subtraction and analysis was performed in excel. |
Ion Mode: | POSITIVE |
MS ID: | MS002154 |
Analysis ID: | AN002311 |
Instrument Name: | ABI Sciex 5600 TripleTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | IDA MS2 method. Ammonium acetate was used for negative ESI solvents. Data processing performed using MS-DIAL and annotated using the in silico library. Blank subtraction and analysis was performed in excel. |
Ion Mode: | NEGATIVE |