Return to study ST001717 main page
MB Sample ID: SA161887
Local Sample ID: | Mito_006_ne |
Subject ID: | SU001794 |
Subject Type: | Cultured cells |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Genotype Strain: | HeLa cell line |
Gender: | Not applicable |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002797 | AN002798 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Waters Acquity I-Class | Waters Acquity I-Class |
Column | Waters Acquity CSH C18 (100 x 2.1mm,1.7um) | Waters Acquity CSH C18 (100 x 2.1mm,1.7um) |
MS Type | ESI | ESI |
MS instrument type | QTOF | QTOF |
MS instrument name | ABI Sciex 5600 TripleTOF | ABI Sciex 5600 TripleTOF |
Ion Mode | POSITIVE | NEGATIVE |
Units | Peak area | Peak area |
MS:
MS ID: | MS002592 |
Analysis ID: | AN002797 |
Instrument Name: | ABI Sciex 5600 TripleTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | m/z range of 80-1500 The following parameter settings were used: ion spray voltage, 5500 V (positive mode) and 4500 V (negative mode); source temperature, 500°C; nebulizer gas pressure, 50 psi; drying gas pressure, 60 psi; and curtain gas pressure, 30 psi. An atmospheric pressure chemical ionization calibration solvent was used to maintain mass accuracy with an automated calibrant delivery system (Sciex). Information-dependent acquisition (IDA) was used to acquire MS/MS spectra for ions. All samples were pooled in equal amounts to generate quality control (QC) samples, which were injected after every 4 samples to calculate the coefficient of variation (CV) and assess analytical reproducibility. |
Ion Mode: | POSITIVE |
MS ID: | MS002593 |
Analysis ID: | AN002798 |
Instrument Name: | ABI Sciex 5600 TripleTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | m/z range of 80-1500 The following parameter settings were used: ion spray voltage, 5500 V (positive mode) and 4500 V (negative mode); source temperature, 500°C; nebulizer gas pressure, 50 psi; drying gas pressure, 60 psi; and curtain gas pressure, 30 psi. An atmospheric pressure chemical ionization calibration solvent was used to maintain mass accuracy with an automated calibrant delivery system (Sciex). Information-dependent acquisition (IDA) was used to acquire MS/MS spectra for ions. All samples were pooled in equal amounts to generate quality control (QC) samples, which were injected after every 4 samples to calculate the coefficient of variation (CV) and assess analytical reproducibility. |
Ion Mode: | NEGATIVE |