MB Sample ID: SA175287
Local Sample ID: | M2622 |
Subject ID: | SU001964 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003051 | AN003052 | AN003053 | AN003054 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | HILIC | HILIC | Reversed phase | Reversed phase |
Chromatography system | Thermo Dionex Ultimate 3000 RS | Thermo Dionex Ultimate 3000 RS | Thermo Dionex Ultimate 3000 RS | Thermo Dionex Ultimate 3000 RS |
Column | SeQuant ZIC-HILIC (100 x 2.1mm,3.5um) | SeQuant ZIC-HILIC (100 x 2.1mm,3.5um) | Agilent Zorbax SBaq (50 x 2.1mm,1.7um) | Agilent Zorbax SBaq (50 x 2.1mm,1.7um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | MS count (log2) | MS count (log2) | MS count (log2) | MS count (log2) |
MS:
MS ID: | MS002838 |
Analysis ID: | AN003051 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Data from each mode were independently analyzed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Median normalization was applied to correct for differential starting material quantity. Missing values were imputed by drawing from a random distribution of low values in the corresponding sample. Data from each mode were merged and metabolites of interest were formally identified by matching fragmentation spectra and retention time to analytical-grade standards when possible or matching experimental MS/MS to fragmentation spectra in publicly available databases. |
Ion Mode: | POSITIVE |
MS ID: | MS002839 |
Analysis ID: | AN003052 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Data from each mode were independently analyzed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Median normalization was applied to correct for differential starting material quantity. Missing values were imputed by drawing from a random distribution of low values in the corresponding sample. Data from each mode were merged and metabolites of interest were formally identified by matching fragmentation spectra and retention time to analytical-grade standards when possible or matching experimental MS/MS to fragmentation spectra in publicly available databases. |
Ion Mode: | NEGATIVE |
MS ID: | MS002840 |
Analysis ID: | AN003053 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Data from each mode were independently analyzed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Median normalization was applied to correct for differential starting material quantity. Missing values were imputed by drawing from a random distribution of low values in the corresponding sample. Data from each mode were merged and metabolites of interest were formally identified by matching fragmentation spectra and retention time to analytical-grade standards when possible or matching experimental MS/MS to fragmentation spectra in publicly available databases. |
Ion Mode: | POSITIVE |
MS ID: | MS002841 |
Analysis ID: | AN003054 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Data from each mode were independently analyzed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Median normalization was applied to correct for differential starting material quantity. Missing values were imputed by drawing from a random distribution of low values in the corresponding sample. Data from each mode were merged and metabolites of interest were formally identified by matching fragmentation spectra and retention time to analytical-grade standards when possible or matching experimental MS/MS to fragmentation spectra in publicly available databases. |
Ion Mode: | NEGATIVE |