Return to study ST002119 main page

MB Sample ID: SA203968

Local Sample ID:CID6_Pos
Subject ID:SU002204
Subject Type:Fish
Subject Species:Danio rerio
Taxonomy ID:7955

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003467 AN003468 AN003469 AN003470
Analysis type MS MS MS MS
Chromatography type HILIC HILIC HILIC HILIC
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Waters Xbridge amide (100 x 2.1mm,3.5um) Waters Xbridge amide (100 x 2.1mm,3.5um) Waters Xbridge amide (100 x 2.1mm,3.5um) Waters Xbridge amide (100 x 2.1mm,3.5um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units ion counts ion counts ion counts ion counts

MS:

MS ID:MS003228
Analysis ID:AN003467
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:It was operated in the full-scan mode (positive/negative switching) with the resolution set at 70 000 (at m/z 200).LC-MS data were analyzed using Sieve 2.0 (Thermo Scientific), and the integrated area under metabolite peak was used to compare the relative abundance of each metabolite in different samples in the same batch.
Ion Mode:POSITIVE
  
MS ID:MS003229
Analysis ID:AN003468
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:It was operated in the full-scan mode (positive/negative switching) with the resolution set at 70 000 (at m/z 200).LC-MS data were analyzed using Sieve 2.0 (Thermo Scientific), and the integrated area under metabolite peak was used to compare the relative abundance of each metabolite in different samples in the same batch.
Ion Mode:NEGATIVE
  
MS ID:MS003230
Analysis ID:AN003469
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:It was operated in the full-scan mode (positive ion mode only) with the resolution set at 70 000 (at m/z 200).LC-MS data were analyzed using Sieve 2.0 (Thermo Scientific), and the integrated area under metabolite peak was used to compare the relative abundance of each metabolite in different samples in the same batch.
Ion Mode:POSITIVE
  
MS ID:MS003231
Analysis ID:AN003470
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:It was operated in the full-scan mode (negative ion mode only) with the resolution set at 70 000 (at m/z 200).LC-MS data were analyzed using Sieve 2.0 (Thermo Scientific), and the integrated area under metabolite peak was used to compare the relative abundance of each metabolite in different samples in the same batch.
Ion Mode:NEGATIVE