Return to study ST002145 main page

MB Sample ID: SA205779

Local Sample ID:shchrebp HG-4
Subject ID:SU002230
Subject Type:Cultured cells
Subject Species:Mus musculus
Taxonomy ID:10090

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003511 AN003512
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Thermo Accucore C18 (100 x 2.1mm,2.6um) Thermo Accucore C18 (100 x 2.1mm,2.6um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Fusion Orbitrap Thermo Fusion Orbitrap
Ion Mode POSITIVE NEGATIVE
Units AUC/ngDNA AUC/ngDNA

MS:

MS ID:MS003269
Analysis ID:AN003511
Instrument Name:Thermo Fusion Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:A Thermo Fisher Scientific Orbitrap Fusion Lumos Tribrid mass spectrometer with heated electrospray ionization source was operated in data- dependent acquisition mode, in positive ionization mode, with scan ranges of 150-827 and 825-1500 m/z. An Orbitrap resolution of 120,000 (FWHM) was used for MS1 acquisition and spray voltages of 3.6kV and -2.9kV were used for positive and negative ionization modes, respectively. For MS2 and MS3 fragmentation a hybridized HCD/CID approach was used. Each sample was analyzed using 4 x 10 µL injections making use of the two scan ranges, in both ionization modes. Data were analyzed using Thermo Scientific LipidSearch software (version 5.0.63) and R scripts written in house. The intensity of each peak was normalized to total lipid signal and to the internal standard.
Ion Mode:POSITIVE
  
MS ID:MS003270
Analysis ID:AN003512
Instrument Name:Thermo Fusion Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:A Thermo Fisher Scientific Orbitrap Fusion Lumos Tribrid mass spectrometer with heated electrospray ionization source was operated in data- dependent acquisition mode, in negative ionization mode, with scan ranges of 150-827 and 825-1500 m/z. An Orbitrap resolution of 120,000 (FWHM) was used for MS1 acquisition and spray voltages of 3.6kV and -2.9kV were used for positive and negative ionization modes, respectively. For MS2 and MS3 fragmentation a hybridized HCD/CID approach was used. Each sample was analyzed using 4 x 10 µL injections making use of the two scan ranges, in both ionization modes. Data were analyzed using Thermo Scientific LipidSearch software (version 5.0.63) and R scripts written in house. The intensity of each peak was normalized to total lipid signal and to the internal standard.
Ion Mode:NEGATIVE