MB Sample ID: SA213241

Local Sample ID:NB_Plasma_EXT_HILIC_Neg_206
Subject ID:SU002324
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003651 AN003652 AN003653 AN003654
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase HILIC HILIC
Chromatography system Thermo Vanquish Thermo Vanquish Thermo Vanquish Thermo Vanquish
Column Waters Acquity BEH C18 (150 x 2mm,1.7um) Waters Acquity BEH C18 (100 x 2mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units Peak area Peak area Peak area Peak area

MS:

MS ID:MS003402
Analysis ID:AN003651
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data processing was performed using MS-DIAL for peak picking, alignment, and identification. For metabolite analysis, in house m/z and retention time libraries were used in addition to MS/MS spectra databases in msp format. MS-DIAL parameters were set as follows: MS1 tolerance, 0.05Da; MS2 tolerance, 0.025 Da; retention time begin, 0 min; retention time end, 100 min; minimum peak height, 10000; mass slice width, 0.1 Da; smoothing level, 3 scans; minimum peak width, 5 scans; sigma window value, 0.5. We considered M−H, M–H2O−H, M+Na-2H, M+Cl, M+FA-H, 2M−H, 2M+FA-H, M−2H, 3M-H adduct in negative ionization mode and M+H, M+Na, M+ACN+H, M+H–H2O, M+H–2H2O, M+2Na-H, M+ACN+Na, M+2ACN+H, 2M+H, M+2H, 2M+ACN+Na in positive ionization mode. Execute retention time correction on IS and IS kit with a RT tolerance of 0.1 min and a mass tolerance of 0.015 Da were performed. In supplementary table X all parameter settings for MS-Dial were reported. For in silico compound annotation of ion features with an acquired tandem mass spectrum MS-FINDER The MS1 and MS2 tolerances were set to 5 and 15 ppm, respectively. Formula finder were exclusively processed with C, H, O, N, P and S atoms.
Ion Mode:POSITIVE
  
MS ID:MS003403
Analysis ID:AN003652
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data processing was performed using MS-DIAL for peak picking, alignment, and identification. For metabolite analysis, in house m/z and retention time libraries were used in addition to MS/MS spectra databases in msp format. MS-DIAL parameters were set as follows: MS1 tolerance, 0.05Da; MS2 tolerance, 0.025 Da; retention time begin, 0 min; retention time end, 100 min; minimum peak height, 10000; mass slice width, 0.1 Da; smoothing level, 3 scans; minimum peak width, 5 scans; sigma window value, 0.5. We considered M−H, M–H2O−H, M+Na-2H, M+Cl, M+FA-H, 2M−H, 2M+FA-H, M−2H, 3M-H adduct in negative ionization mode and M+H, M+Na, M+ACN+H, M+H–H2O, M+H–2H2O, M+2Na-H, M+ACN+Na, M+2ACN+H, 2M+H, M+2H, 2M+ACN+Na in positive ionization mode. Execute retention time correction on IS and IS kit with a RT tolerance of 0.1 min and a mass tolerance of 0.015 Da were performed. In supplementary table X all parameter settings for MS-Dial were reported. For in silico compound annotation of ion features with an acquired tandem mass spectrum MS-FINDER The MS1 and MS2 tolerances were set to 5 and 15 ppm, respectively. Formula finder were exclusively processed with C, H, O, N, P and S atoms.
Ion Mode:NEGATIVE
  
MS ID:MS003404
Analysis ID:AN003653
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data processing was performed using MS-DIAL for peak picking, alignment, and identification. For metabolite analysis, in house m/z and retention time libraries were used in addition to MS/MS spectra databases in msp format. MS-DIAL parameters were set as follows: MS1 tolerance, 0.05Da; MS2 tolerance, 0.025 Da; retention time begin, 0 min; retention time end, 100 min; minimum peak height, 10000; mass slice width, 0.1 Da; smoothing level, 3 scans; minimum peak width, 5 scans; sigma window value, 0.5. We considered M−H, M–H2O−H, M+Na-2H, M+Cl, M+FA-H, 2M−H, 2M+FA-H, M−2H, 3M-H adduct in negative ionization mode and M+H, M+Na, M+ACN+H, M+H–H2O, M+H–2H2O, M+2Na-H, M+ACN+Na, M+2ACN+H, 2M+H, M+2H, 2M+ACN+Na in positive ionization mode. Execute retention time correction on IS and IS kit with a RT tolerance of 0.1 min and a mass tolerance of 0.015 Da were performed. In supplementary table X all parameter settings for MS-Dial were reported. For in silico compound annotation of ion features with an acquired tandem mass spectrum MS-FINDER The MS1 and MS2 tolerances were set to 5 and 15 ppm, respectively. Formula finder were exclusively processed with C, H, O, N, P and S atoms.
Ion Mode:POSITIVE
  
MS ID:MS003405
Analysis ID:AN003654
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data processing was performed using MS-DIAL for peak picking, alignment, and identification. For metabolite analysis, in house m/z and retention time libraries were used in addition to MS/MS spectra databases in msp format. MS-DIAL parameters were set as follows: MS1 tolerance, 0.05Da; MS2 tolerance, 0.025 Da; retention time begin, 0 min; retention time end, 100 min; minimum peak height, 10000; mass slice width, 0.1 Da; smoothing level, 3 scans; minimum peak width, 5 scans; sigma window value, 0.5. We considered M−H, M–H2O−H, M+Na-2H, M+Cl, M+FA-H, 2M−H, 2M+FA-H, M−2H, 3M-H adduct in negative ionization mode and M+H, M+Na, M+ACN+H, M+H–H2O, M+H–2H2O, M+2Na-H, M+ACN+Na, M+2ACN+H, 2M+H, M+2H, 2M+ACN+Na in positive ionization mode. Execute retention time correction on IS and IS kit with a RT tolerance of 0.1 min and a mass tolerance of 0.015 Da were performed. In supplementary table X all parameter settings for MS-Dial were reported. For in silico compound annotation of ion features with an acquired tandem mass spectrum MS-FINDER The MS1 and MS2 tolerances were set to 5 and 15 ppm, respectively. Formula finder were exclusively processed with C, H, O, N, P and S atoms.
Ion Mode:NEGATIVE