Return to study ST002243 main page
MB Sample ID: SA214368
Local Sample ID: | Patient_Positive_OP_12 |
Subject ID: | SU002329 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003661 | AN003662 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 |
Column | Thermo Accucore C18 (100 x 2.1mm,2.6um) | Thermo Accucore C18 (100 x 2.1mm,2.6um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive HF hybrid Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | intensity | intensity |
MS:
MS ID: | MS003412 |
Analysis ID: | AN003661 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Samples were analyzed using a Q Exactive HF (QE-HF) (Thermo Scientific, Waltham, MA) equipped with a heated electro-spray ionization (HESI) source operated in both positive and negative ion mode. For DDA library generation (untargeted lipidomics), data acquisition was performed on the pooled QC samples in Full Scan/ddMS2 mode @ 120,000 resolutions. The Full Scan settings as follows: AGC target = 1e6; Maximum IT = 250 ms; scan range = 250 to 1800 m/z. Top 20 MS/MS spectral (dd-MS2) @ 15000 were generated with AGC target = 1e5, Maximum IT=25 ms, and (N)CE/stepped nce = 20, 30, 40v. For untargeted lipid analysis, LipidSearch 4.2 (Thermo Scientific, Waltham, MA) was used for peak detection, identification, alignment, and quantification. Well annotated lipids (MS spectral match) were used to generate a inclusion list (Supplementary Table 4) for targeted lipidomics analysis. Targeted lipidomics were performed in Full scan + PRM modes. The PRM settings were as follows: resolution = 15000, AGC target = 2e5, Maximum IT=25 ms, loop count = 36, isolation window = 2.0, (N)CE was optimized for each lipid class. |
Ion Mode: | POSITIVE |
MS ID: | MS003413 |
Analysis ID: | AN003662 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Samples were analyzed using a Q Exactive HF (QE-HF) (Thermo Scientific, Waltham, MA) equipped with a heated electro-spray ionization (HESI) source operated in both positive and negative ion mode. For DDA library generation (untargeted lipidomics), data acquisition was performed on the pooled QC samples in Full Scan/ddMS2 mode @ 120,000 resolutions. The Full Scan settings as follows: AGC target = 1e6; Maximum IT = 250 ms; scan range = 250 to 1800 m/z. Top 20 MS/MS spectral (dd-MS2) @ 15000 were generated with AGC target = 1e5, Maximum IT=25 ms, and (N)CE/stepped nce = 20, 30, 40v. For untargeted lipid analysis, LipidSearch 4.2 (Thermo Scientific, Waltham, MA) was used for peak detection, identification, alignment, and quantification. Well annotated lipids (MS spectral match) were used to generate a inclusion list (Supplementary Table 4) for targeted lipidomics analysis. Targeted lipidomics were performed in Full scan + PRM modes. The PRM settings were as follows: resolution = 15000, AGC target = 2e5, Maximum IT=25 ms, loop count = 36, isolation window = 2.0, (N)CE was optimized for each lipid class. |
Ion Mode: | NEGATIVE |