MB Sample ID: SA242928

Local Sample ID:OilPalm_Drought_Control_R1_POS
Subject ID:SU002519
Subject Type:Plant
Subject Species:Elaeis guineensis Jacq.
Taxonomy ID:NCBI:txid51953

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003955 AN003956
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Shimadzu Nexera X2 Shimadzu Nexera X2
Column Waters Acquity BEH C18 (150 x 2mm, 1.7um) Waters Acquity BEH C18 (150 x 2mm, 1.7um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Bruker maXis Impact qTOF Bruker maXis Impact qTOF
Ion Mode POSITIVE NEGATIVE
Units Peak intensity Peak intensity

MS:

MS ID:MS003690
Analysis ID:AN003955
Instrument Name:Bruker maXis Impact qTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:High-resolution mass spectrometry (HRMS) was performed in a MaXis 4G Q-TOF MS system (Bruker Daltonics, Germany) using an electrospray source in the positive and negative ion modes (ESI(+)–MS and ESI(−)–MS). The MS instrument settings used were: endplate offset, 500 V; capillary voltage, 3800 V; nebulizer pressure, 4 bar; dry gas flow, 9 L/min, dry temperature, 200 °C; and column temperature, 40 °C. The acquisition spectra rate was 3.00 Hz, monitoring a mass range from 70 to 1200 m/z. Sodium formate solution (10 mM NaOH solution in 50/50 v/v isopropanol/water containing 0.2% formic acid) was directly injected through a 6-port valve at the beginning of each chromatographic run to external calibration. UHPLC–MS data was acquired by the HyStar Application version 3.2 (Bruker Daltonics, Germany), and data processing was done using Data Analysis 4.2 (Bruker Daltonics, Germany).
Ion Mode:POSITIVE
  
MS ID:MS003691
Analysis ID:AN003956
Instrument Name:Bruker maXis Impact qTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:High-resolution mass spectrometry (HRMS) was performed in a MaXis 4G Q-TOF MS system (Bruker Daltonics, Germany) using an electrospray source in the positive and negative ion modes (ESI(+)–MS and ESI(−)–MS). The MS instrument settings used were: endplate offset, 500 V; capillary voltage, 3800 V; nebulizer pressure, 4 bar; dry gas flow, 9 L/min, dry temperature, 200 °C; and column temperature, 40 °C. The acquisition spectra rate was 3.00 Hz, monitoring a mass range from 70 to 1200 m/z. Sodium formate solution (10 mM NaOH solution in 50/50 v/v isopropanol/water containing 0.2% formic acid) was directly injected through a 6-port valve at the beginning of each chromatographic run to external calibration. UHPLC–MS data was acquired by the HyStar Application version 3.2 (Bruker Daltonics, Germany), and data processing was done using Data Analysis 4.2 (Bruker Daltonics, Germany).
Ion Mode:NEGATIVE