Return to study ST002551 main page

MB Sample ID: SA256193

Local Sample ID:159200_1_GREENL_CTL_OD_7dpi_NEG
Subject ID:SU002651
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Gender:Male and female

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004200 AN004201
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Thermo Vanquish Thermo Vanquish
Column Thermo Accucore Amide HILIC (150 x 2.1mm, 2.6um) Thermo Accucore Amide HILIC (150 x 2.1mm, 2.6um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units µg/ml µg/ml

MS:

MS ID:MS003947
Analysis ID:AN004200
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The samples were run using a Q ExactiveTM mass spectrometer coupled to a heated electrospray ionization (HESI) source. The spray voltage was set to 3.50 kV, capillary temperature to 350°C, sheath gas to 55, aux gas to 14, sweep gas to 4, and S-Lens RF Level to 30.0. The mass range was set to 67 – 1000 m/z, resolution 140,000 for full scan and 35,000 for ddMS2. AGC target was set to 1e6 for full scan and 2e5 for ddMS2. The max injection time (IT) was 100 seconds for full scan mode and 50 seconds for ddMS2. The number of microscans was 2, and normalized collision energy (NCE) was set to 20, 35, and 50. Samples were run in both positive and negative ion mode separately. The parameters for negative mode were the same except the spray voltage, which was set to 2.50 kV and capillary temperature to 380°C. Metabolites were identified from their Thermo.RAW scans using Compound DiscovererTM 3.3 software. Extraction blanks were used to determine and correct for reagent effects, allow for the creation of exclusions lists, mark background components, and filters the background components from the results table in Compound DiscovererTM 3.3. Pooled QCs were used for initial compound normalization and identification. All non-identified compounds were removed.
Ion Mode:POSITIVE
  
MS ID:MS003948
Analysis ID:AN004201
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The samples were run using a Q ExactiveTM mass spectrometer coupled to a heated electrospray ionization (HESI) source. The spray voltage was set to 3.50 kV, capillary temperature to 350°C, sheath gas to 55, aux gas to 14, sweep gas to 4, and S-Lens RF Level to 30.0. The mass range was set to 67 – 1000 m/z, resolution 140,000 for full scan and 35,000 for ddMS2. AGC target was set to 1e6 for full scan and 2e5 for ddMS2. The max injection time (IT) was 100 seconds for full scan mode and 50 seconds for ddMS2. The number of microscans was 2, and normalized collision energy (NCE) was set to 20, 35, and 50. Samples were run in both positive and negative ion mode separately. The parameters for negative mode were the same except the spray voltage, which was set to 2.50 kV and capillary temperature to 380°C. Metabolites were identified from their Thermo.RAW scans using Compound DiscovererTM 3.3 software. Extraction blanks were used to determine and correct for reagent effects, allow for the creation of exclusions lists, mark background components, and filters the background components from the results table in Compound DiscovererTM 3.3. Pooled QCs were used for initial compound normalization and identification. All non-identified compounds were removed.
Ion Mode:NEGATIVE
  logo