MB Sample ID: SA299554
Local Sample ID: | DMSO_iRBC_p_1 |
Subject ID: | SU002899 |
Subject Type: | Cultured cells |
Subject Species: | Plasmodium falciparum |
Taxonomy ID: | 5833 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN004542 | AN004543 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | HILIC | HILIC |
Chromatography system | Thermo Dionex Ultimate 3000 RS | Thermo Dionex Ultimate 3000 RS |
Column | ZIC-pHILIC (150 x 4.6mm,5um) equipped with a guard (SeQuant,Merck) | ZIC-pHILIC (150 x 4.6mm,5um) equipped with a guard (SeQuant,Merck) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | peak height | peak height |
MS:
MS ID: | MS004289 |
Analysis ID: | AN004542 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Metabolite detection was performed using a high-resolution Q Exactive MS (ThermoFisher) in both positive and negative ionisation modes. The PBQC sample was run periodically throughout each LC-MS batch to monitor signal reproducibility and support downstream metabolite identification. Extraction solvent blank samples were also analysed to identify possible contaminating chemical species. To aid in metabolite identification, approximately 250 authentic metabolite standards were analysed prior to each LC-MS batch and their peaks and retention time manually checked using the ToxID software (ThermoFisher). Metabolomics data were analysed using the IDEOM workflow (Creek et al. 2012). Briefly, the IDEOM processing pipeline uses msconvert for conversion of raw files to mzXML files and split polarity, XCMS to extract raw peak intensities and mzMatch to align samples, filter noise, fill missing peaks and annotate related peaks. Manual assessment of spiked internal standards, total ion chromatograms and median peak heights ensured signal reproducibility and allowed exclusion of outlier samples. LC MS peak heights representing metabolite abundances were normalised by median peak height. High confidence metabolite identification (MSI level 1) was made by matching accurate mass and retention time to authentic metabolite standards. Putative identifications (MSI level 2) for metabolites lacking standards were based on exact mass and predicted retention times. |
Ion Mode: | POSITIVE |
MS ID: | MS004290 |
Analysis ID: | AN004543 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Metabolite detection was performed using a high-resolution Q Exactive MS (ThermoFisher) in both positive and negative ionisation modes. The PBQC sample was run periodically throughout each LC-MS batch to monitor signal reproducibility and support downstream metabolite identification. Extraction solvent blank samples were also analysed to identify possible contaminating chemical species. To aid in metabolite identification, approximately 250 authentic metabolite standards were analysed prior to each LC-MS batch and their peaks and retention time manually checked using the ToxID software (ThermoFisher). Metabolomics data were analysed using the IDEOM workflow (Creek et al. 2012). Briefly, the IDEOM processing pipeline uses msconvert for conversion of raw files to mzXML files and split polarity, XCMS to extract raw peak intensities and mzMatch to align samples, filter noise, fill missing peaks and annotate related peaks. Manual assessment of spiked internal standards, total ion chromatograms and median peak heights ensured signal reproducibility and allowed exclusion of outlier samples. LC MS peak heights representing metabolite abundances were normalised by median peak height. High confidence metabolite identification (MSI level 1) was made by matching accurate mass and retention time to authentic metabolite standards. Putative identifications (MSI level 2) for metabolites lacking standards were based on exact mass and predicted retention times. |
Ion Mode: | NEGATIVE |