Return to study ST002809 main page
MB Sample ID: SA301602
Local Sample ID: | MUSC-00308 |
Subject ID: | SU002916 |
Subject Type: | Mammal |
Subject Species: | Mouse/canine |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN004566 | AN004567 | AN004568 | AN004569 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | Reversed phase | HILIC |
Chromatography system | Waters Acquity | Waters Acquity | Waters Acquity | Waters Acquity |
Column | Waters Acquity BEH C18 (100 x 2mm, 1.7um) | Waters Acquity BEH C18 (100 x 2mm, 1.7um) | Waters Acquity BEH C18 (100 x 2mm, 1.7um) | Waters Acquity BEH Amide (150 x 2.1mm, 1.7um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | POSITIVE | NEGATIVE | NEGATIVE |
Units | Normalized/scaled raw area counts | Normalized/scaled raw area counts | Normalized/scaled raw area counts | Normalized/scaled raw area counts |
MS:
MS ID: | MS004312 |
Analysis ID: | AN004566 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Proprietary analytical software for integration and peak picking (Metabolon). Normalized raw area counts for each sample are normalized by Bradford protein concentration. Each metabolite is then rescaled to set the median equal to 1. Lastly, missing values are imputed with the minimum. |
Ion Mode: | POSITIVE |
MS ID: | MS004313 |
Analysis ID: | AN004567 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Proprietary analytical software for integration and peak picking (Metabolon). Normalized raw area counts for each sample are normalized by Bradford protein concentration. Each metabolite is then rescaled to set the median equal to 1. Lastly, missing values are imputed with the minimum. |
Ion Mode: | POSITIVE |
MS ID: | MS004314 |
Analysis ID: | AN004568 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Proprietary analytical software for integration and peak picking (Metabolon). Normalized raw area counts for each sample are normalized by Bradford protein concentration. Each metabolite is then rescaled to set the median equal to 1. Lastly, missing values are imputed with the minimum. |
Ion Mode: | NEGATIVE |
MS ID: | MS004315 |
Analysis ID: | AN004569 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Proprietary analytical software for integration and peak picking (Metabolon). Normalized raw area counts for each sample are normalized by Bradford protein concentration. E.ach metabolite is then rescaled to set the median equal to 1. Lastly, missing values are imputed with the minimum. |
Ion Mode: | NEGATIVE |