Return to study ST002498 main page
MB Sample ID: SA308149
Local Sample ID: | C00467 |
Subject ID: | SU002954 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Gender: | Male |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN004654 | AN004655 | AN004656 | AN004657 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | Reversed phase | HILIC |
Chromatography system | Waters Acquity | Waters Acquity | Waters Acquity | Waters Acquity |
Column | Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um) | Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um) | Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um) | Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | POSITIVE | NEGATIVE | NEGATIVE |
Units | peak area | peak area | peak area | peak area |
MS:
MS ID: | MS004401 |
Analysis ID: | AN004654 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Metabolon (LC/MS Pos early). Mass spectrometry was performed using a Q-Exactive (Thermo Scientific, Waltham, MA) high resolution/accurate mass spectrometer interfaced with a heated electrospray ionization (HESI-II) source and Orbitrap mass analyzer operated at 35,000 mass resolution. The linearity of the instrument performance standards has been shown previously. Immediately prior to analysis, dried samples were reconstituted in solvents compatible with each of the four methods, as described below. Each reconstitution solvent contained several instrument performance standards at fixed concentrations to ensure injection and chromatographic consistency, and to aid peak alignment. The injection volume was 5 mL with a 2x loop overfill. |
Ion Mode: | POSITIVE |
Analysis Protocol File: | preprocessing_workflow.docx |
MS ID: | MS004402 |
Analysis ID: | AN004655 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Metabolon (LC/MS Pos late). Mass spectrometry was performed using a Q-Exactive (Thermo Scientific, Waltham, MA) high resolution/accurate mass spectrometer interfaced with a heated electrospray ionization (HESI-II) source and Orbitrap mass analyzer operated at 35,000 mass resolution. The linearity of the instrument performance standards has been shown previously. Immediately prior to analysis, dried samples were reconstituted in solvents compatible with each of the four methods, as described below. Each reconstitution solvent contained several instrument performance standards at fixed concentrations to ensure injection and chromatographic consistency, and to aid peak alignment. The injection volume was 5 mL with a 2x loop overfill. |
Ion Mode: | POSITIVE |
Analysis Protocol File: | preprocessing_workflow.docx |
MS ID: | MS004403 |
Analysis ID: | AN004656 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Metabolon (LC/MS Neg). Mass spectrometry was performed using a Q-Exactive (Thermo Scientific, Waltham, MA) high resolution/accurate mass spectrometer interfaced with a heated electrospray ionization (HESI-II) source and Orbitrap mass analyzer operated at 35,000 mass resolution. The linearity of the instrument performance standards has been shown previously. Immediately prior to analysis, dried samples were reconstituted in solvents compatible with each of the four methods, as described below. Each reconstitution solvent contained several instrument performance standards at fixed concentrations to ensure injection and chromatographic consistency, and to aid peak alignment. The injection volume was 5 mL with a 2x loop overfill. |
Ion Mode: | NEGATIVE |
Analysis Protocol File: | preprocessing_workflow.docx |
MS ID: | MS004404 |
Analysis ID: | AN004657 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Metabolon (LC/MS Polar). Mass spectrometry was performed using a Q-Exactive (Thermo Scientific, Waltham, MA) high resolution/accurate mass spectrometer interfaced with a heated electrospray ionization (HESI-II) source and Orbitrap mass analyzer operated at 35,000 mass resolution. The linearity of the instrument performance standards has been shown previously. Immediately prior to analysis, dried samples were reconstituted in solvents compatible with each of the four methods, as described below. Each reconstitution solvent contained several instrument performance standards at fixed concentrations to ensure injection and chromatographic consistency, and to aid peak alignment. The injection volume was 5 mL with a 2x loop overfill. |
Ion Mode: | NEGATIVE |
Analysis Protocol File: | preprocessing_workflow.docx |