MB Sample ID: SA323221

Local Sample ID:2A2-01-10479
Subject ID:SU003089
Subject Type:Mammal
Subject Species:BALB/C nude mice

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004886
Analysis type MS
Chromatography type Reversed phase
Chromatography system Bruker Elute
Column Hamilton Intensity Solo 2 C18 (100 x 2.1mm, 1.8um)
MS Type ESI
MS instrument type QTOF
MS instrument name Bruker timsTOF
Ion Mode POSITIVE
Units AU

MS:

MS ID:MS004630
Analysis ID:AN004886
Instrument Name:Bruker timsTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The ESI source conditions were set with a capillary voltage of 4500 V, drying gas flow rate of 10.0 l/min at 220°C, nebulizer pressure of 2.2 bar, and the End Plate offset at 500 V. Sodium formate (10 mM) was injected at the beginning of each sample run and used as a calibrant for internal calibration during data processing. The MS acquisition process consisted of two phases. First, an auto MS scan lasting from 0 to 0.3 minutes was utilized for calibrating sodium formate. The second phase encompassed auto MS/MS scanning with CID acquisition, including fragmentation, which extended from 0.3 to 30 minutes. Both acquisition phases were conducted in positive mode at a rate of 12 Hz. The automatic mass scan range within each run spanned from 50 to 1300 m/z, with a precursor ion width of ±0.5, a cycle time of 0.5 seconds, and a threshold of 400 counts. Active exclusion was initiated after three spectra and lifted after 0.2 minutes. For MS2 acquisition, a data-dependent acquisition (DDA) approach was employed, with collision energy settings varying between 100% and 250% and being set at 20 eV. TRX-2101/RT-28-calibrants from Nova Medical Testing Inc. for the Bruker T-ReX LC-QTOF were injected before sample analysis to assess the column's performance, reversed-phase liquid chromatography (RPLC) separation, multipoint retention time calibration, and the mass spectrometer. Additionally, TRX-3112-R/MS Certified Human serum solution for Bruker T-ReX LC-QTOF (provided by Nova Medical Testing Inc.) was prepared from pooled human blood and administered before sample analysis to validate the performance of the LC-MS instruments. The analysis followed a randomized sequence order, commencing with five injections of solvent A (0.1% formic acid in deionized water) to facilitate apparatus equilibration. Subsequently, five injections of the pooled QC sample were carried out. Furthermore, one QC injection was conducted every (9-10 samples) to assess the consistency of the analysis.
Ion Mode:POSITIVE