Combined analysis:

Analysis ID AN004950 AN004951
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Waters ACQUITY UPLC BEH C18(100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH C18(100 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Peak area Peak area

MS:

MS ID:MS004690
Analysis ID:AN004950
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:All samples were analyzed in full scan positive and negative ion modes with spray voltages +3.0kV and -3.0kV, respectively, at 70,000 resolution at m/z 200, the scan range was m/z 100-1500 and source temperature at 300 °C. Tandem mass spectra were collected via criterion based on data-dependent acquisition for the top-10 ions with stepped normalized collision energy 20, 25, and 30, an isolation window of 1Da, dynamic exclusion of 6 s, and using IE-Omics for the generation of exclusion lists in iterative-exclusion experiments (Koelmel, Kroeger, Gill, et al., 2017). Extracted Lipid Data Analysis LipidMatch software was implemented to identify and integrate the detected lipids (Koelmel, Kroeger, Ulmer, et al., 2017). The peak areas were normalized relative to the internal standards of the same subclass as the lipid of interest. For lipids that did not have an internal standard of the same subclass, the internal standard with the closest chemical structure was used (i.e., internal standard with the same head group). Otherwise, the internal standard with the closest chromatographic retention time (same ionization polarity) was used for analytes without a corresponding internal standard of the same lipid subclass. The plasma lipid concentrations were reported as µg/mL.
Ion Mode:POSITIVE
Analysis Protocol File:MS Metadata.txt
  
MS ID:MS004691
Analysis ID:AN004951
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:All samples were analyzed in full scan positive and negative ion modes with spray voltages +3.0kV and -3.0kV, respectively, at 70,000 resolution at m/z 200, the scan range was m/z 100-1500 and source temperature at 300 °C. Tandem mass spectra were collected via criterion based on data-dependent acquisition for the top-10 ions with stepped normalized collision energy 20, 25, and 30, an isolation window of 1Da, dynamic exclusion of 6 s, and using IE-Omics for the generation of exclusion lists in iterative-exclusion experiments (Koelmel, Kroeger, Gill, et al., 2017). Extracted Lipid Data Analysis LipidMatch software was implemented to identify and integrate the detected lipids (Koelmel, Kroeger, Ulmer, et al., 2017). The peak areas were normalized relative to the internal standards of the same subclass as the lipid of interest. For lipids that did not have an internal standard of the same subclass, the internal standard with the closest chemical structure was used (i.e., internal standard with the same head group). Otherwise, the internal standard with the closest chromatographic retention time (same ionization polarity) was used for analytes without a corresponding internal standard of the same lipid subclass. The plasma lipid concentrations were reported as µg/mL.
Ion Mode:NEGATIVE
Analysis Protocol File:MS Metadata.txt