Return to study ST003147 main page
MB Sample ID: SA340745
Local Sample ID: | m22-L025_SO_07 |
Subject ID: | SU003264 |
Subject Type: | Cultured cells |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Age Or Age Range: | 60 |
Gender: | Female |
Cell Biosource Or Supplier: | ATCC |
Cell Strain Details: | BT-474, breast cancer cell line |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN005163 | AN005164 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | HILIC | HILIC |
Chromatography system | Thermo Dionex Ultimate 3000 RS | Thermo Dionex Ultimate 3000 RS |
Column | Merck SeQuant ZIC-pHILIC (150 x 2.1mm,5um) | Merck SeQuant ZIC-pHILIC (150 x 2.1mm,5um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive HF-X Orbitrap | Thermo Q Exactive HF-X Orbitrap |
Ion Mode | NEGATIVE | POSITIVE |
Units | AU | AU |
MS:
MS ID: | MS004899 |
Analysis ID: | AN005163 |
Instrument Name: | Thermo Q Exactive HF-X Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The HESI ion source voltage was set to the following parameters: 3,600 V in both polarity modes, sheath gas 30, auxiliary gas 5, spare gas 0, probe heater 200 °C, capillary temperature 325 °C, S-Lens RF level 65. The mass spectrometer was set to acquire data in the polarity-switching mode averaging two microscans with 60,000 resolution, automatic gain control (AGC) target 5e6, scan range 72-1080 m/z, and maximum orbitrap injection time (IT) 200 ms. Data were converted into the mzXML format by ProteoWizard and analyzed in MAVEN. |
Ion Mode: | NEGATIVE |
Ion Source Temperature: | 200 |
Ion Spray Voltage: | 3600 |
Ionization: | Both |
Source Temperature: | 200 |
Automatic Gain Control: | 5e6 |
Dataformat: | RAW |
MS ID: | MS004900 |
Analysis ID: | AN005164 |
Instrument Name: | Thermo Q Exactive HF-X Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The HESI ion source voltage was set to the following parameters: 3,600 V in both polarity modes, sheath gas 30, auxiliary gas 5, spare gas 0, probe heater 200 °C, capillary temperature 325 °C, S-Lens RF level 65. The mass spectrometer was set to acquire data in the polarity-switching mode averaging two microscans with 60,000 resolution, automatic gain control (AGC) target 5e6, scan range 72-1080 m/z, and maximum orbitrap injection time (IT) 200 ms. Data were converted into the mzXML format by ProteoWizard and analyzed in MAVEN. |
Ion Mode: | POSITIVE |
Ion Source Temperature: | 200 |
Ion Spray Voltage: | 3600 |
Ionization: | Both |
Source Temperature: | 200 |
Automatic Gain Control: | 5e6 |
Dataformat: | RAW |