Return to study ST003152 main page

MB Sample ID: SA340990

Local Sample ID:06_Fasnall_MCF7_Tum_Gluc_1h_F_1072
Subject ID:SU003269
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Genotype Strain:NOD Scid Gamma (NSG)
Age Or Age Range:~4.5 months
Weight Or Weight Range:24.3 +/- 1.9 g (mean +/- SD)
Gender:Female
Animal Housing:Wistar Animal Facility
Species Group:Rodents (order Rodentia)

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005171 AN005172
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS
Column Merck SeQuant ZIC-pHILIC (150 x 2.1mm,5um) Merck SeQuant ZIC-pHILIC (150 x 2.1mm,5um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF-X Orbitrap Thermo Q Exactive HF-X Orbitrap
Ion Mode NEGATIVE POSITIVE
Units AU AU

MS:

MS ID:MS004906
Analysis ID:AN005171
Instrument Name:Thermo Q Exactive HF-X Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The HESI ion source voltage was set to the following parameters: 3,600 V in both polarity modes, sheath gas 30, auxiliary gas 5, spare gas 0, probe heater 200 °C, capillary temperature 325 °C, S-Lens RF level 65. The mass spectrometer was set to acquire data in the polarity-switching mode averaging two microscans with 60,000 resolution, automatic gain control (AGC) target 5e6, scan range 72-1080 m/z, and maximum orbitrap injection time (IT) 200 ms. Data were converted into the mzXML format by ProteoWizard and analyzed in MAVEN.
Ion Mode:NEGATIVE
Ion Source Temperature:200
Ion Spray Voltage:3600
Ionization:Both
Source Temperature:200
Automatic Gain Control:5e6
Dataformat:RAW
  
MS ID:MS004907
Analysis ID:AN005172
Instrument Name:Thermo Q Exactive HF-X Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The HESI ion source voltage was set to the following parameters: 3,600 V in both polarity modes, sheath gas 30, auxiliary gas 5, spare gas 0, probe heater 200 °C, capillary temperature 325 °C, S-Lens RF level 65. The mass spectrometer was set to acquire data in the polarity-switching mode averaging two microscans with 60,000 resolution, automatic gain control (AGC) target 5e6, scan range 72-1080 m/z, and maximum orbitrap injection time (IT) 200 ms. Data were converted into the mzXML format by ProteoWizard and analyzed in MAVEN.
Ion Mode:POSITIVE
Ion Source Temperature:200
Ion Spray Voltage:3600
Ionization:Both
Source Temperature:200
Automatic Gain Control:5e6
Dataformat:RAW
  logo