Return to study ST003162 main page

MB Sample ID: SA342895

Local Sample ID:WL_RPLC_POS_WT_2
Subject ID:SU003281
Subject Type:Insect
Subject Species:Drosophila melanogaster
Taxonomy ID:7227

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005187 AN005188 AN005189 AN005190
Analysis type MS MS MS MS
Chromatography type HILIC HILIC Reversed phase Reversed phase
Chromatography system Thermo Vanquish Flex UHPLC Systems Thermo Vanquish Flex UHPLC Systems Agilent 1290 Infinity II Agilent 1290 Infinity II
Column HILICON iHILIC-(P) Classic (100 x 2.1mm,5um) HILICON iHILIC-(P) Classic (100 x 2.1mm,5um) Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.7um) Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap QTOF Orbitrap
MS instrument name Thermo Orbitrap ID-X tribrid Thermo Orbitrap ID-X tribrid Agilent 6545 QTOF Thermo Orbitrap ID-X tribrid
Ion Mode NEGATIVE NEGATIVE POSITIVE POSITIVE
Units peak area peak area peak area peak area

MS:

MS ID:MS004920
Analysis ID:AN005187
Instrument Name:Thermo Orbitrap ID-X tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were collected with the following MS source settings: spray voltage, -2.8 kV; sheath gas, 50; auxiliary gas, 10; sweep gas, 1; ion transfer tube temperature, 300°C; vaporizer temperature, 200°C; mass range, 67 – 1000 Da; resolution, 120,000; maximum injection time, 200 ms; isolation window, 1.6 Da. XCMS and Skyline software were used for data processing
Ion Mode:NEGATIVE
  
MS ID:MS004921
Analysis ID:AN005188
Instrument Name:Thermo Orbitrap ID-X tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were collected with the following MS source settings: spray voltage, -2.8 kV; sheath gas, 50; auxiliary gas, 10; sweep gas, 1; ion transfer tube temperature, 300°C; vaporizer temperature, 200°C; mass range, 67 – 1000 Da; resolution, 120,000; maximum injection time, 200 ms; isolation window, 1.6 Da. XCMS and Skyline software were used for data processing
Ion Mode:NEGATIVE
  
MS ID:MS004922
Analysis ID:AN005189
Instrument Name:Agilent 6545 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Data were collected with the following MS source settings: gas temp, 250°C; drying gas, 11 l/min; nebulizer, 35 psi; sheath gas temp, 300°C; sheath gas flow 12 l/min; capillary voltage, 3 kV; nozzle voltage, 500 V; isolation window, 1.3 Da. XCMS and Skyline software were used for data processing
Ion Mode:POSITIVE
  
MS ID:MS004923
Analysis ID:AN005190
Instrument Name:Thermo Orbitrap ID-X tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were collected with the following MS source settings: spray voltage, -3 kV; sheath gas, 50; auxiliary gas, 10; sweep gas, 1; ion transfer tube temperature, 300°C; vaporizer temperature, 350°C; mass range, 100 – 1500 Da; resolution, 120,000; maximum injection time, 150 ms; isolation window, 1.6 Da. XCMS and Skyline software were used for data processing
Ion Mode:POSITIVE