Return to study ST003168 main page
MB Sample ID: SA343057
Local Sample ID: | young_2 |
Subject ID: | SU003287 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Age Or Age Range: | Young donors (aged 25 years or younger) and older donors (aged 50 years or older). |
Gender: | Male and female |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN005198 | AN005199 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Waters HPLC C18 (100 x 2.1mm, 1.7um) | Waters HPLC C18 (100 x 2.1mm, 1.7um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive HF-X Orbitrap | Thermo Q Exactive HF-X Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | pmoles/mg tissue | nanomoles/mg of tissue |
MS:
MS ID: | MS004931 |
Analysis ID: | AN005198 |
Instrument Name: | Thermo Q Exactive HF-X Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Data was acquired in full scan/data-dependent MS2 mode (full scan resolution 60,000 FWHM, scan range 220–1600 m/z). Sample order was randomised, and data was collected in both positive and negative mode for each sample. The ten most abundant ions in each cycle were subjected to MS2, with an isolation window of 1.4 m/z, collision energy 30 eV, resolution 17,500 FWHM, maximum integration time 110 ms and dynamic exclusion window 10 s. An exclusion list of background ions was used based on a solvent blank. An inclusion list was used for all internal standards. LipidSearch software (version 4.2, Thermo Fisher) was used for lipid annotation, chromatogram alignment, and peak integration. Lipid annotation required both accurate precursor ion mass (tolerance 5 ppm) and diagnostic product ions (tolerance 8 ppm). Individual lipids were expressed as ratios to the class-specific internal standard, then multiplied by the amount of internal standard to calculate molar amounts for each lipid. Lipid levels were expressed as nmoles/mg tissue. |
Ion Mode: | POSITIVE |
MS ID: | MS004932 |
Analysis ID: | AN005199 |
Instrument Name: | Thermo Q Exactive HF-X Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Data was acquired in full scan/data-dependent MS2 mode (full scan resolution 60,000 FWHM, scan range 220–1600 m/z). Sample order was randomised, and data was collected in both positive and negative mode for each sample. The ten most abundant ions in each cycle were subjected to MS2, with an isolation window of 1.4 m/z, collision energy 30 eV, resolution 17,500 FWHM, maximum integration time 110 ms and dynamic exclusion window 10 s. An exclusion list of background ions was used based on a solvent blank. An inclusion list was used for all internal standards. LipidSearch software (version 4.2, Thermo Fisher) was used for lipid annotation, chromatogram alignment, and peak integration. Lipid annotation required both accurate precursor ion mass (tolerance 5 ppm) and diagnostic product ions (tolerance 8 ppm). Individual lipids were expressed as ratios to the class-specific internal standard, then multiplied by the amount of internal standard to calculate molar amounts for each lipid. Lipid levels were expressed as nmoles/mg tissue. |
Ion Mode: | NEGATIVE |