Return to study ST003177 main page

MB Sample ID: SA344539

Local Sample ID:POS_575
Subject ID:SU003296
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005215 AN005216
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system SCIEX ExionLC UHPLC SCIEX ExionLC UHPLC
Column Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Triple quadrupole Triple quadrupole
MS instrument name ABI SCIEX Triple Quad 5500+ LC-MS/MS ABI SCIEX Triple Quad 5500+ LC-MS/MS
Ion Mode POSITIVE NEGATIVE
Units peak area Peak area

MS:

MS ID:MS004948
Analysis ID:AN005215
Instrument Name:ABI SCIEX Triple Quad 5500+ LC-MS/MS
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Within each batch, normalization was performed by dividing the level of each metabolite by the average value of the first and last QC samples in that batch. Subsequently, a cross-sample total sum correction was conducted for all metabolites. Then, the data was mean-centered and divided by the standard deviation of each variable for standardization. Finally, a log10 transformation was applied to the data. We further removed metabolites with a coefficient of variation (CV) greater than 0.35 and any metabolites with more than 50% missing values within any group (RA, at-risk of RA, and Health). For analyses intolerant to missing data, any missing values are substituted with 1/5 of the minimum positive value of their corresponding variables.
Ion Mode:POSITIVE
  
MS ID:MS004949
Analysis ID:AN005216
Instrument Name:ABI SCIEX Triple Quad 5500+ LC-MS/MS
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Within each batch, normalization was performed by dividing the level of each metabolite by the average value of the first and last QC samples in that batch. Subsequently, a cross-sample total sum correction was conducted for all metabolites. Then, the data was mean-centered and divided by the standard deviation of each variable for standardization. Finally, a log10 transformation was applied to the data. We further removed metabolites with a coefficient of variation (CV) greater than 0.35 and any metabolites with more than 50% missing values within any group (RA, at-risk of RA, and Health). For analyses intolerant to missing data, any missing values are substituted with 1/5 of the minimum positive value of their corresponding variables.
Ion Mode:NEGATIVE