Return to study ST003190 main page

MB Sample ID: SA347879

Local Sample ID:C-5m-1-IP7-FigS2b
Subject ID:SU003309
Subject Type:Plant
Subject Species:Arabidopsis thaliana
Taxonomy ID:3702

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005238
Analysis type MS
Chromatography type HILIC
Chromatography system Agilent 1290 Infinity
Column Agilent InfinityLab Poroshell 120 EC-C18 (100 x 3mm,2.7um)
MS Type Other
MS instrument type HPLC-MS/MS
MS instrument name Agilent 5973
Ion Mode POSITIVE
Units mg/g

MS:

MS ID:MS004971
Analysis ID:AN005238
Instrument Name:Agilent 5973
Instrument Type:HPLC-MS/MS
MS Type:Other
MS Comments:InsPs were detected using Hydrophilic Interaction High Performance Liquid Chromatography-Tandem Mass Spectrometry on an Agilent 1290 infinity HPLC system coupled to an Agilent 6460 triple Quad LC-MS/MS using InfinityLab Poroshell 120 HILIC-Z (2.1 × 100) column (Agilent Technologies, USA). Nitrogen was used as the sheath gas and drying gas. The nebulizer pressure was set to 45 psi and the flow rate of drying gas was 5 L / min. The flow rate and temperature of the sheath gas were 11 L / min and 350℃, respectively. Chromatographic separation was carried out on a HPLC column (100 × 2.1 mm, 2.7 µm). The column temperature was 35℃. The mobile phases consisted of (A) ammonium acetate in distilled water (pH 10.0) and (B) Acetonitrile. The gradient program was as follows: 0-10 min, 90 % → 55 % of B; 10-12 min, 55 % → 90 % of B; 12-20 min, 90 % of B. The flow rate was set at 0.3 ml / min, and the injection volume was 10 μl. Mass spectrometric detection was completed by use of an electrospray ionization (ESI) source in negative ion multiple-reaction monitoring (MRM) mode. InsPs were identified based on comparison to known InsPs species. The mass spectrometry parameters corresponding to different InsPs show as below: InsP3 (MRM: 419 -> 321, 419 -> 337, Acquisition time is 6-7 min); InsP4 (MRM: 499 -> 401, 499 -> 417, Acquisition time is 6-7 min); InsP5 (MRM: 579 -> 480.9, 579 -> 382.8, Acquisition time is 6-7 min); InsP6 (MRM: 659 -> 560.8, 659 -> 577, Acquisition time is 6-7 min); InsP7 (MRM: 739 -> 575, 739 -> 657, Acquisition time is 5-6 min); InsP8 (MRM: 819 -> 737, 819 -> 655, Acquisition time is 4-5 min). According to the regression equation calculated from the standard sample, substitute the response value of the sample into the equation to convert the corresponding concentration.
Ion Mode:POSITIVE
  logo