Return to study ST003210 main page
MB Sample ID: SA351593
Local Sample ID: | UM074 |
Subject ID: | SU003329 |
Subject Type: | Cultured cells |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN005262 | AN005263 | AN005264 | AN005265 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | HILIC | HILIC | Reversed phase | Reversed phase |
Chromatography system | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 |
Column | Agilent InfinityLab Poroshell 120 HILIC-Z (100 x 2.1mm, 2.7um) | Agilent InfinityLab Poroshell 120 HILIC-Z (100 x 2.1mm, 2.7um) | Phenomenex Kinetex C18 (100 x 2.1mm,2.6um) | Phenomenex Kinetex C18 (100 x 2.1mm,2.6um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive HF hybrid Orbitrap |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | Peak area | Peak area | Peak area | Peak area |
MS:
MS ID: | MS004993 |
Analysis ID: | AN005262 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | All operations and acquisitions were controlled by Xcalibur 2.0.7 (Thermo Fisher Scientific, Bremen, Germany).UPLC-HRMS data were analyzed using MS-DIAL software after conversion to mzML file format using MSConvert (Version 3.0, ProteiWizard). |
Ion Mode: | POSITIVE |
Analysis Protocol File: | MS_analysis_protocol.pdf |
MS ID: | MS004994 |
Analysis ID: | AN005263 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | All operations and acquisitions were controlled by Xcalibur 2.0.7 (Thermo Fisher Scientific, Bremen, Germany).UPLC-HRMS data were analyzed using MS-DIAL software after conversion to mzML file format using MSConvert (Version 3.0, ProteiWizard). |
Ion Mode: | NEGATIVE |
Analysis Protocol File: | MS_analysis_protocol.pdf |
MS ID: | MS004995 |
Analysis ID: | AN005264 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | All operations and acquisitions were controlled by Xcalibur 2.0.7 (Thermo Fisher Scientific, Bremen, Germany).UPLC-HRMS data were analyzed using MS-DIAL software after conversion to mzML file format using MSConvert (Version 3.0, ProteiWizard). |
Ion Mode: | POSITIVE |
Analysis Protocol File: | MS_analysis_protocol.pdf |
MS ID: | MS004996 |
Analysis ID: | AN005265 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | All operations and acquisitions were controlled by Xcalibur 2.0.7 (Thermo Fisher Scientific, Bremen, Germany).UPLC-HRMS data were analyzed using MS-DIAL software after conversion to mzML file format using MSConvert (Version 3.0, ProteiWizard). |
Ion Mode: | NEGATIVE |
Analysis Protocol File: | MS_analysis_protocol.pdf |