Summary of Study ST000143
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000219. The data can be accessed directly via it's Project DOI: 10.21228/M8359Z This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
Study ID | ST000143 |
Study Title | Metabolic analysis of Normal Mouse Lung Fiboblasts with/without TGFbeta treatment (Part 1) |
Study Type | Glycolysis/TCA/Nucleotide analysis (tissue/cells) |
Study Summary | This study is a part of series performed for the same researcher through pilot/feasibility grant program, so the publication is relevant reference for other studies, see the project for this study. This specific experiment is a small pilot study to establish method performance, it includes four biological replicas of identical cell cultures after the identical treatment and a single tissue sample. |
Institute | University of Michigan |
Department | Biomedical Research Core Facilities |
Laboratory | Metabolomics core |
Last Name | Kachman |
First Name | Maureen |
Address | 6300 Brehm Tower, 1000 Wall Street, Ann Arbor, MI 48105-5714 |
mkachman@umich.edu | |
Submit Date | 2015-03-13 |
Num Groups | 4 |
Total Subjects | 21 |
Raw Data Available | Yes |
Raw Data File Type(s) | d |
Uploaded File Size | 5.2 G |
Analysis Type Detail | GC-MS/LC-MS |
Release Date | 2015-03-13 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN000226 | AN000227 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | HILIC | GC |
Chromatography system | Agilent 1260 | Agilent 7890A |
Column | Phenomenex Luna NH2 (150 x 1mm,3um) | Agilent DB5-MS (30m × 0.25mm, 0.25um) |
MS Type | ESI | EI |
MS instrument type | QTOF | Single quadrupole |
MS instrument name | Agilent 6520 QTOF | Agilent 5975C |
Ion Mode | NEGATIVE | POSITIVE |
Units | uM | uM |
MS:
MS ID: | MS000177 |
Analysis ID: | AN000226 |
Instrument Name: | Agilent 6520 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
Ion Mode: | NEGATIVE |
Acquisition Parameters File: | QTOF-002-HILIC-35min-1mm.m.zip |
Processing Parameters File: | EX00294-MassHunterQuant-GlyTCA-LCMS-DataAnalysis-Method.m.zip |
MS ID: | MS000178 |
Analysis ID: | AN000227 |
Instrument Name: | Agilent 5975C |
Instrument Type: | Single quadrupole |
MS Type: | EI |
Ion Mode: | POSITIVE |
Tube Lens Voltage: | Positive |
Acquisition Parameters File: | ALPHA_KETO_ACIDS-FULL.M.zip |
Processing Parameters File: | EX00294-MassHunterQuant-GlyTCA-GCMS-DataAnalysis-Method.m.zip |