This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000482. The data can be accessed directly via it's Project DOI: 10.21228/M8RG76 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
Study ID | ST000683 |
Study Title | Untargeted Lipidomics for hepatic lipid profile wild type versus knockout |
Study Type | MS analysis |
Study Summary | Use untargeted lipidomics to investigate differences in hepatic lipid profile between wild type and knockout mice. Mice were fed with high fat diet for 10 weeks and sacrificed under randomly fed condition. Liver were harvested freshly and frozen into liquid nitrogen immediately. Each sample was combined liver tissues from three individual mice in the same group. |
Institute | University of Michigan |
Department | Biomedical Research Core Facilities |
Laboratory | Metabolomics core |
Last Name | Kachman |
First Name | Maureen |
Address | 6300 Brehm Tower, 1000 Wall Street, Ann Arbor, MI 48105-5714 |
mkachman@med.umich.edu | |
Phone | (734) 232-8175 |
Submit Date | 2017-06-05 |
Num Groups | 3 |
Total Subjects | 2 |
Raw Data Available | Yes |
Raw Data File Type(s) | wiff |
Analysis Type Detail | LC-MS |
Release Date | 2017-12-06 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN001052 | AN001053 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Shimadzu CTO-20A Nexera X2 | Shimadzu CTO-20A Nexera X2 |
Column | Waters Acquity HSS T3 (50 x 2.1mm,1.8um) | Waters Acquity HSS T3 (50 x 2.1mm,1.8um) |
MS Type | ESI | ESI |
MS instrument type | Triple TOF | Triple TOF |
MS instrument name | ABI Sciex 5600+ TripleTOF | ABI Sciex 5600+ TripleTOF |
Ion Mode | NEGATIVE | POSITIVE |
Units | peak area | peak area |
MS:
MS ID: | MS000947 |
Analysis ID: | AN001052 |
Instrument Name: | ABI Sciex 5600+ TripleTOF |
Instrument Type: | Triple TOF |
MS Type: | ESI |
Ion Mode: | NEGATIVE |
Analysis Protocol File: | A004_-_Shotgun_Lipidomics.pdf |
MS ID: | MS000948 |
Analysis ID: | AN001053 |
Instrument Name: | ABI Sciex 5600+ TripleTOF |
Instrument Type: | Triple TOF |
MS Type: | ESI |
Ion Mode: | POSITIVE |
Analysis Protocol File: | A004_-_Shotgun_Lipidomics.pdf |