Summary of Study ST001241
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000830. The data can be accessed directly via it's Project DOI: 10.21228/M8D68Q This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001241 |
Study Title | Global Metabolic Analysis Trisomy 21 - Cohort 3, Plasma |
Study Summary | Global metabolic analysis of plasma from individuals with and without trisomy 21. |
Institute | University of Colorado Denver |
Last Name | Culp-Hill |
First Name | Rachel |
Address | 12801 E 17th Ave L18-9403D, Aurora, Colorado, 80045, USA |
rachel.hill@cuanschutz.edu | |
Phone | 303-724-5798 |
Submit Date | 2019-08-13 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2019-08-21 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002061 | AN002062 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) | Phenomenex Kinetex C18 (150 x 2.1mm,2.6um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | relative abundance | relative abundance |
MS:
MS ID: | MS001912 |
Analysis ID: | AN002061 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The Q Exactive mass spectrometer (Thermo Fisher Scientific, San Jose, CA, USA) was operated in positive ion mode using electrospray ionization, scanning in Full MS mode (1μscan) from 65 to 975 m/z at 70,000 resolution, with 4 kV spray voltage, 45 sheath gas, 15 auxiliary gas. MS analysis and data elaboration were performed as described74,75. Calibration was performed prior to analysis using the PierceTM Positive Ion Calibration Solution (Thermo Fisher Scientific). |
Ion Mode: | POSITIVE |
MS ID: | MS001913 |
Analysis ID: | AN002062 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The Q Exactive mass spectrometer (Thermo Fisher Scientific, San Jose, CA, USA) was operated in negative ion mode using electrospray ionization, scanning in Full MS mode (1μscan) from 65 to 975 m/z at 70,000 resolution, with 4 kV spray voltage, 45 sheath gas, 15 auxiliary gas. MS analysis and data elaboration were performed as described74,75. Calibration was performed prior to analysis using the PierceTM Negative Ion Calibration Solution (Thermo Fisher Scientific). |
Ion Mode: | NEGATIVE |