Summary of Study ST001405
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000955. The data can be accessed directly via it's Project DOI: 10.21228/M87X1R This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001405 |
Study Title | MDM2-Dependent Rewiring of Metabolomic and Lipidomic Profiles in Dedifferentiated Liposarcoma Models |
Study Summary | Dedifferentiated liposarcoma (DDLPS) is an aggressive mesenchymal cancer marked by amplification of MDM2, an inhibitor of the tumor suppressor TP53. DDLPS patients with higher MDM2 amplification have lower chemotherapy sensitivity and worse outcome than patients with lower MDM2 amplification. We hypothesized that MDM2 amplification levels may be associated with changes in DDLPS metabolism. Six patient-derived DDLPS cell line models were subject to comprehensive metabolomic (Metabolon) and lipidomic (SCIEX 5600 TripleTOF-MS) profiling to assess associations with MDM2 amplification and their responses to metabolic perturbations. Comparing metabolomic profiles between MDM2 higher and lower amplification cells yielded a total of 23 differentially abundant metabolites across both panels (FDR < 0.05, log2 FC < 0.75), including ceramides, glycosylated ceramides, and sphingomyelins. Disruption of lipid metabolism through statin administration resulted in a chemo-sensitive phenotype in MDM2 lower cell lines only, suggesting that lipid metabolism may be a large contributor to the more aggressive nature of MDM2 higher DDLPS tumors. This study is the first to provide comprehensive metabolomic and lipidomic characterization of DDLPS cell lines and provides evidence for MDM2-dependent differential molecular mechanisms that are critical factors in chemoresistance and could thus affect patient outcome. |
Institute | The Ohio State University |
Last Name | Patt |
First Name | Andrew |
Address | 136 W. Pacemont Rd, Columbus, OH, 43202, USA |
patt.14@osu.edu | |
Phone | 5183664293 |
Submit Date | 2020-05-22 |
Raw Data Available | Yes |
Raw Data File Type(s) | mzXML |
Analysis Type Detail | LC-MS |
Release Date | 2020-07-07 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002347 | AN002348 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Shimadzu Prominence 20 UFLCXR | Shimadzu Prominence 20 UFLCXR |
Column | Waters XBridge C18 (50 x 2.1mm,3um) | Waters XBridge C18 (50 x 2.1mm,3um) |
MS Type | ESI | ESI |
MS instrument type | QTOF | QTOF |
MS instrument name | ABI Sciex 5600 TripleTOF | ABI Sciex 5600 TripleTOF |
Ion Mode | POSITIVE | NEGATIVE |
Units | ppm | ppm |
MS:
MS ID: | MS002189 |
Analysis ID: | AN002347 |
Instrument Name: | ABI Sciex 5600 TripleTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | The capillary voltage was set at 5.5 kV, with a declustering potential of 80V. The mass spectrometer was operated in IDA (Information Dependent Acquisition) mode with a 100 ms survey scan from 100 to 1200 m/z, and up to 20 MS/MS product ion scans (100 ms) per duty cycle using a collision energy of 50V with a 20V spread. |
Ion Mode: | POSITIVE |
MS ID: | MS002190 |
Analysis ID: | AN002348 |
Instrument Name: | ABI Sciex 5600 TripleTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | The capillary voltage was set at 4.5 kV, with a declustering potential of 80V. The mass spectrometer was operated in IDA (Information Dependent Acquisition) mode with a 100 ms survey scan from 100 to 1200 m/z, and up to 20 MS/MS product ion scans (100 ms) per duty cycle using a collision energy of 50V with a 20V spread. |
Ion Mode: | NEGATIVE |