Summary of Study ST001632
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001043. The data can be accessed directly via it's Project DOI: 10.21228/M8W41Q This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
Study ID | ST001632 |
Study Title | Lipidomics of Ginseng Total Secondary Saponins on Myocardial Ischemia Rat |
Study Summary | Cardioprotective Effect of Ginseng Total Secondary Saponins on Myocardial Ischemia Rat via Regulating Disturbed Lipids Based on Lipidomics. |
Institute | Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College |
Last Name | Wang |
First Name | Zhe |
Address | No.2 nanwei street, xichen district, Beijing, China |
wangzhe@imm.ac.cn | |
Phone | +861083154880 |
Submit Date | 2020-11-22 |
Raw Data Available | Yes |
Raw Data File Type(s) | d |
Analysis Type Detail | LC-MS |
Release Date | 2023-01-02 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002667 | AN002668 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Agilent 1100 | Thermo Accela 1250 |
Column | Peeke C8 SR (150×3.0mm, 3μm) | Waters Xterra MS C8 (100 x 2.1mm,3.5um) |
MS Type | ESI | ESI |
MS instrument type | Triple quadrupole | LTQ-FT |
MS instrument name | Agilent 6410 QQQ | Thermo LTQ-FT |
Ion Mode | POSITIVE | UNSPECIFIED |
Units | pmol/ml(PL) & pmol/mg(HL) | pmol/ml(PS) & pmol/mg(HS) |
MS:
MS ID: | MS002466 |
Analysis ID: | AN002667 |
Instrument Name: | Agilent 6410 QQQ |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | The parameters for electrospray ionization tandem MS in positive ion mode were as follows: gas temperature, 350 ℃; gas flow rate, 10 l/min; nebulizer, 30 psi; and capillary voltage, 4000V. Multiple reaction monitoring was performed using the characteristic precursor-to-product ion transitions, optimized fragmentor voltages, and collision energies. |
Ion Mode: | POSITIVE |
MS ID: | MS002467 |
Analysis ID: | AN002668 |
Instrument Name: | Thermo LTQ-FT |
Instrument Type: | LTQ-FT |
MS Type: | ESI |
MS Comments: | The LTQ-FT was run in full-scan mode at 100000 resolution from m/z50–1200 with MS parameters: sheath gas flow rate, 50 arb; aux gas flow rate, 20 arb; sweep gas flow rate, 3 arb; capillary temperature, 275 ℃ in both positive and negative mode. And spray voltage, 4.5kV; capillary voltage, 35.0V; tube lens, 120V were used for the positive mode. Spray voltage, -4.0kV; capillary voltage, -35.0V; tube lens, -120V were used for the negative mode. |
Ion Mode: | UNSPECIFIED |