This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001150. The data can be accessed directly via it's Project DOI: 10.21228/M82690 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
Study ID | ST001819 |
Study Title | EC and PVC from 14-15 month-old APOE3/3, APOE3/4 and APOE4/4 mice |
Study Summary | We performed a targeted lipidomic analysis on EC and PVC tissue from 14-15 month old APOE3/3, APOE3/4, and APOE4/4 mice. |
Institute | Columbia University |
Last Name | Nuriel |
First Name | Tal |
Address | 630 W 168th St., P&S 12-430 |
tn2283@cumc.columbia.edu | |
Phone | 2123045683 |
Submit Date | 2021-06-02 |
Analysis Type Detail | LC-MS |
Release Date | 2021-06-10 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002951 | AN002952 | AN002953 |
---|---|---|---|
Analysis type | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | HILIC |
Chromatography system | Agilent 1260 | Agilent 1260 | Agilent 1260 |
Column | Agilent Eclipse XDB-C18 (100 x 3.0mm) | Agilent Eclipse XDB-C18 (100 x 3.0mm) | Phenomenex Luna NH2 (150 x 2.1mm,3um) |
MS Type | ESI | ESI | ESI |
MS instrument type | Triple quadrupole | Triple quadrupole | Triple quadrupole |
MS instrument name | Agilent 6490 QQQ | Agilent 6490 QQQ | Agilent 6490 QQQ |
Ion Mode | NEGATIVE | POSITIVE | POSITIVE |
Units | area under the curve | area under the curve | area under the curve |
MS:
MS ID: | MS002741 |
Analysis ID: | AN002951 |
Instrument Name: | Agilent 6490 QQQ |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | Lipid profiling was performed using an Agilent 1260 HPLC coupled to an Agilent 6490 triple quadrupole (QQQ) mass spectrometer (41). Each sample was run through three separate chromatographic conditions (reverse-phase negative mode, reverse-phase positive mode and normal-phase positive mode) for the effective quantification of 337 distinct lipids from 28 lipid subclasses, as previously described (41). Individual lipid species were measured by multiple reaction monitoring transitions. |
Ion Mode: | NEGATIVE |
MS ID: | MS002742 |
Analysis ID: | AN002952 |
Instrument Name: | Agilent 6490 QQQ |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | Lipid profiling was performed using an Agilent 1260 HPLC coupled to an Agilent 6490 triple quadrupole (QQQ) mass spectrometer (41). Each sample was run through three separate chromatographic conditions (reverse-phase negative mode, reverse-phase positive mode and normal-phase positive mode) for the effective quantification of 337 distinct lipids from 28 lipid subclasses, as previously described (41). Individual lipid species were measured by multiple reaction monitoring transitions. |
Ion Mode: | POSITIVE |
MS ID: | MS002743 |
Analysis ID: | AN002953 |
Instrument Name: | Agilent 6490 QQQ |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | Lipid profiling was performed using an Agilent 1260 HPLC coupled to an Agilent 6490 triple quadrupole (QQQ) mass spectrometer (41). Each sample was run through three separate chromatographic conditions (reverse-phase negative mode, reverse-phase positive mode and normal-phase positive mode) for the effective quantification of 337 distinct lipids from 28 lipid subclasses, as previously described (41). Individual lipid species were measured by multiple reaction monitoring transitions. |
Ion Mode: | POSITIVE |