Summary of Study ST002758
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001719. The data can be accessed directly via it's Project DOI: 10.21228/M8HF01 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002758 |
Study Title | Metabolic responses of normal rat kidneys to a high salt intake (Plasma) |
Study Type | Time-course metabolomics experiment |
Study Summary | In this study, novel methods were developed which allowed continuous (24/7) measurement of arterial blood pressure and renal blood flow in freely moving rats and the intermittent collection of arterial and renal venous blood to estimate kidney metabolic fluxes of O2 and metabolites. Specifically, the study determined the effects of a high salt (HS; 4.0% NaCl) diet upon whole kidney O2 consumption and arterial and renal venous plasma metabolomic profiles of normal Sprague-Dawley rats. A separate group of rats was studied to determine changes in the cortex and outer medulla tissue metabolomic profiles before and following the switch from a 0.4% to 4.0% NaCl diet. |
Institute | Medical College of Wisconsin |
Department | Physiology |
Laboratory | Dr. Allen W. Cowley |
Last Name | Cowley |
First Name | Allen |
Address | 8701 W. Watertown Plank Rd, Milwaukee, WI 53226 |
cowley@mcw.edu | |
Phone | 4149558277 |
Submit Date | 2023-06-26 |
Raw Data Available | Yes |
Raw Data File Type(s) | mzML |
Analysis Type Detail | LC-MS |
Release Date | 2023-07-02 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN004475 | AN004476 | AN004477 | AN004478 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | HILIC | HILIC |
Chromatography system | Thermo Vanquish | Thermo Vanquish | Thermo Vanquish | Thermo Vanquish |
Column | Agilent InfinityLab Poroshell 120 EC-C18 (2.1 x 50 mm; 2.7-Micron) | Agilent InfinityLab Poroshell 120 HILIC-Z (2.1 x 50 mm; 2.7 micron; #689775-924) | Agilent InfinityLab Poroshell 120 HILIC-Z (2.1 x 50 mm; 2.7 micron; #689775-924) | Agilent InfiinityLab Poroshell 120 HILIC-Z (2.1 x 50 mm; 2.7 micron; #689775-924) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | Area | Area | Area | Area |
MS:
MS ID: | MS004222 |
Analysis ID: | AN004475 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | C18 positive plasma data: The tandem mass spectrometry RAW data files (consisting of MS1 and MS2 spectra collected) were analyzed using Thermo Compound Discoverer (v3.2.0.421). The MS1 and MS2 data was searched against the Thermo mzCloud database, ChemSpider database, Metabolika Pathways, and mzLogic predicted composition in the Compound Discoverer workflow. |
Ion Mode: | POSITIVE |
MS ID: | MS004223 |
Analysis ID: | AN004476 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | C18 negative plasma data: The tandem mass spectrometry RAW data files (consisting of MS1 and MS2 spectra collected) were analyzed using Thermo Compound Discoverer (v3.2.0.421). The MS1 and MS2 data was searched against the Thermo mzCloud database, ChemSpider database, Metabolika Pathways, and mzLogic predicted composition in the Compound Discoverer workflow. |
Ion Mode: | NEGATIVE |
MS ID: | MS004224 |
Analysis ID: | AN004477 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | HILIC positive plasma data: The tandem mass spectrometry RAW data files (consisting of MS1 and MS2 spectra collected) were analyzed using Thermo Compound Discoverer (v3.2.0.421). The MS1 and MS2 data was searched against the Thermo mzCloud database, ChemSpider database, Metabolika Pathways, and mzLogic predicted composition in the Compound Discoverer workflow. |
Ion Mode: | POSITIVE |
MS ID: | MS004225 |
Analysis ID: | AN004478 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | HILIC negative plasma data: The tandem mass spectrometry RAW data files (consisting of MS1 and MS2 spectra collected) were analyzed using Thermo Compound Discoverer (v3.2.0.421). The MS1 and MS2 data was searched against the Thermo mzCloud database, ChemSpider database, Metabolika Pathways, and mzLogic predicted composition in the Compound Discoverer workflow. |
Ion Mode: | NEGATIVE |