Summary of Study ST003098
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001923. The data can be accessed directly via it's Project DOI: 10.21228/M85149 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST003098 |
Study Title | Lactiplantibacillus plantarum intervention on cecum tryptophans of gestational fecal microbiome transplant germ-free mice |
Study Summary | The study aims to investigate whether administration of probiotic L. plantarum could influence profiling of cecum tryptophans of germ-free mice. L. plantarum intervention during gestation of humanized GF mice showed no significant difference on tryptophans’s content. |
Institute | Beijing Sanyuan Foods Co. Ltd |
Last Name | Lijun |
First Name | Chen |
Address | 8th yingchang street, yinghai district |
chenlijun@sanyuan.com.cn | |
Phone | 01056306594 |
Submit Date | 2024-02-18 |
Raw Data Available | Yes |
Raw Data File Type(s) | mzML |
Analysis Type Detail | LC-MS |
Release Date | 2024-03-08 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN005069 |
---|---|
Analysis type | MS |
Chromatography type | LC |
Chromatography system | Thermo Vanquish |
Column | Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.8um) |
MS Type | ESI |
MS instrument type | Triple quadrupole |
MS instrument name | ABI Sciex 5000 |
Ion Mode | POSITIVE |
Units | μg/g |
MS:
MS ID: | MS004807 |
Analysis ID: | AN005069 |
Instrument Name: | ABI Sciex 5000 |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | Ion Source Temperature 500°C, Ion Source Voltage 5500 V, Collision Gas 6 psi, Curtain Gas 30 psi, Atomizing Gas and Auxiliary Gas both 50 psi. 45 arbitrary units (AU), 13 AU, 1 AU, 350 °C, and 350 °C for sheath gas, aux gas, sweep gas, ion transfer tube, and vaporizer temperature, respectively. The ion source was operated using heated ESI with an ion spray voltage set at 5500 V in positive ion mode. Polarity switching and scheduled selected reaction monitoring (SRM) were employed.The raw data were firstly converted to mzXML format by MSConvert in the ProteoWizard software package (v3.0.8789) (Adusumilli et al., 2017) and processed using XCMS (Domingo-Almenara et al., 2020) for feature detection, retention time correction and alignment. |
Ion Mode: | POSITIVE |