Summary of Study ST003185

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001983. The data can be accessed directly via it's Project DOI: 10.21228/M8D72S This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003185
Study TitleA multimodal drug-diet-immunotherapy combination restrains melanoma progression and metastasis - plasma lipidomics
Study SummaryLipidomics profiling of immunocompetent B16F10 model of melanoma to examine lipid levels in mouse plasma following reduced oleic acid content in diet combined with the stearyl CoA desaturase inhibitor CAY10566.
Institute
University of Colorado Anschutz Medical Campus
Last NameHaines
First NameJulie
Address12801 E 17th Ave, Room 1303, Aurora, Colorado, 80045, USA
Emailjulie.haines@cuanschutz.edu
Phone3037243339
Submit Date2024-05-02
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2024-05-18
Release Version1
Julie Haines Julie Haines
https://dx.doi.org/10.21228/M8D72S
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005231 AN005232 AN005233
Analysis type MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish Thermo Vanquish
Column Phenomenex Kinetex C18 (30 x 2.1mm,1.7um) Phenomenex Kinetex C18 (30 x 2.1mm,1.7um) Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.8um)
MS Type ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode NEGATIVE POSITIVE NEGATIVE
Units peak area peak area peak area

MS:

MS ID:MS004964
Analysis ID:AN005231
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The Q Exactive was run independently in positive and negative ion mode, scanning using full MS from 125-1500 m/z at 70,000 resolution and top 10 data-dependent MS2 at 17,500 resolution. Electrospray ionization was achieved with 45 Arb sheath gas, 25 Arb auxiliary gas, and 4 kV spray voltage. Calibration was performed prior to the run using the PierceTM Positive and Negative Ion Calibration Solutions (Thermo Fisher Scientific). Run order of samples was randomized and technical replicates were injected after every 4 samples to assess quality control.
Ion Mode:NEGATIVE
  
MS ID:MS004965
Analysis ID:AN005232
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The Q Exactive was run independently in positive and negative ion mode, scanning using full MS from 125-1500 m/z at 70,000 resolution and top 10 data-dependent MS2 at 17,500 resolution. Electrospray ionization was achieved with 45 Arb sheath gas, 25 Arb auxiliary gas, and 4 kV spray voltage. Calibration was performed prior to the run using the PierceTM Positive and Negative Ion Calibration Solutions (Thermo Fisher Scientific). Run order of samples was randomized and technical replicates were injected after every 4 samples to assess quality control.
Ion Mode:POSITIVE
  
MS ID:MS004966
Analysis ID:AN005233
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The Q Exactive was run independently in positive and negative ion mode, scanning using full MS from 125-1500 m/z at 70,000 resolution and top 10 data-dependent MS2 at 17,500 resolution. Electrospray ionization was achieved with 45 Arb sheath gas, 25 Arb auxiliary gas, and 4 kV spray voltage. Calibration was performed prior to the run using the PierceTM Positive and Negative Ion Calibration Solutions (Thermo Fisher Scientific). Run order of samples was randomized and technical replicates were injected after every 4 samples to assess quality control.
Ion Mode:NEGATIVE